저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

APC

APC BX850M UPS 850VA 510W 120V 8 NEMA outlets

SKU CH-AG6P-HFPPR MPN BX850M

Provides 850 VA / 510 W battery backup with AVR, LCD status, USB management and 1103 J surge protection across eight NEMA outlets

  • International Version120V
  • Input Voltage Range88 -139V
  • Input Frequency60 Hz +/- 3 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating850 VA
  • Watts510 Watts
  • 850 VA / 510 W capacity protects workstations and networking gear
  • Automatic Voltage Regulation corrects brownouts without draining the battery
  • Eight NEMA 5-15R outlets — four with battery backup, four surge-only
  • LCD status screen plus USB port for PowerChute monitoring and graceful shutdown
  • 1,103-joule surge rating plus RJ-45 and coax protection for data lines

Compact Tower UPS for Home and Small Business

The APC BX850M is an 850 VA, 510 watt battery backup designed to protect computers, networking gear and entertainment systems from outages, surges and voltage fluctuations. Its compact tower form factor fits on a desk or shelf while providing eight NEMA 5-15R outlets, four of which deliver battery-backed power with automatic voltage regulation.

Stepped Sine Wave Output with AVR and USB Management

In normal operation the unit corrects input voltages between 88 and 139 V without using the battery, preserving runtime for actual blackouts. The stepped approximated sine wave output keeps attached equipment running during an outage, while the USB port enables monitoring and graceful shutdown through PowerChute Personal Edition software. Surge protection is rated at 1103 joules for both AC and data lines.

2.1 Minutes Runtime at Full 510 Watt Load

At maximum rated load the sealed lead-acid battery provides 2.1 minutes of backup, extending to 8.9 minutes at half load, with a 12 hour recharge cycle. This runtime profile suits users who need just enough time to save work and shut down safely, not those who require extended operation through long outages. Buyers needing longer runtimes at high loads should consider higher-capacity units.

주요 특징

  • 850 VA / 510 W capacity protects workstations and networking gear
  • Automatic Voltage Regulation corrects brownouts without draining the battery
  • Eight NEMA 5-15R outlets — four with battery backup, four surge-only
  • LCD status screen plus USB port for PowerChute monitoring and graceful shutdown
  • 1,103-joule surge rating plus RJ-45 and coax protection for data lines

사양

BrandAPC
SeriesBack UPS Pro
ModelBX850M
International Version120V
Input Voltage Range88 -139V
Input Frequency60 Hz +/- 3 Hz
Input ConnectionNEMA 5-15P
VA Rating850 VA
Watts510 Watts
Output Voltage120V
Output Frequency60 Hz
Outlets8
Outlet Type4 x NEMA 5-15R (Battery Backup)
4 x NEMA 5-15R (selector_surgetitle)
Battery TypeSealed Lead Acid
Battery Run TimeAt Full load: 2.1 minutes
At half load: 8.9 minutes
Battery Recharge Time12 Hour(s)
Interface PortUSB
ApprovalsCalifornia (CEC) Battery Charger, ENERGY STAR (USA), FCC Part 15 Class B, UL 1778
Data Line ProtectionNetwork line - 10 / 100 / 1000 Base-T Ethernet (RJ-45 connector)
Coaxial cable for CATV / SATV / modem / Audio-Video (coax connector)
Surge Energy Rating1103 Joules
FeaturesEnergy Management Function
Battery-protected and surge-only outlets
Boost Automatic Voltage Regulation (AVR)
LCD Status Display
Green mode
Dimensions7.48" x 3.58" x 12.20"
Weight14.99 lbs.
배송 무게7.68 kg
포장 크기437 × 251 × 147 mm

이 모델의 다른 버전

같은 라인업에서 4개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How do I connect the USB cable so PowerChute can shut down my PC before the battery runs out?

Plug the USB cable into the UPS and your computer, install PowerChute Personal Edition, then configure the shutdown timer to trigger well before the 2.1 minutes at full load or 8.9 minutes at half load.

When will the sealed lead acid battery need replacing and how long does a full recharge take?

Expect three to five years of service; after a complete discharge the battery requires 12 hours to reach full charge again.

What happens if my equipment draws more than 510 watts during an outage?

The UPS will trip its overload protection and cut output because 510 watts is the maximum real power the inverter can supply.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.