TFX form-factor 500 W unit with full-range active PFC, an 80 mm fan, and fixed cables including 20+4-pin, 8-pin, two 6+2-pin PCIe, three SATA and three Molex connectors

  • TypeATX
  • Delivers 500W for demanding components
  • Full-range active PFC handles 90-264V input
  • Single +12V rail provides 33A output
  • Fixed cables include 20+4pin, 8pin and 2x 6+2 PCIe
  • 80mm fan forces air through compact 175.26mm chassis

APEVIA TFX 500W Power Supply

This compact TFX unit delivers 500W through fixed cables with full-range active PFC. It fits slim desktop chassis that require the shorter TFX form factor. The single 80 mm fan provides forced-air cooling across the metal housing.

Suits small-form-factor upgrades needing 500W

Builders replacing a TFX unit in a slim tower or mini-PC will find the connector mix covers a modern motherboard, CPU, GPU and multiple drives. Systems requiring modular cables, higher wattage or standard ATX dimensions cannot use this model.

Fixed-cable TFX layout with 20+4-pin.

The harness includes three SATA and three 4-pin Molex plugs alongside the primary connectors. If your build demands detachable cables or a different connector count, this power supply will not match.

주요 특징

  • Delivers 500W for demanding components
  • Full-range active PFC handles 90-264V input
  • Single +12V rail provides 33A output
  • Fixed cables include 20+4pin, 8pin and 2x 6+2 PCIe
  • 80mm fan forces air through compact 175.26mm chassis

사양

TypeATX

이 상품에 대한 질문

How do I fit the 175.26 mm TFX unit into my case and connect the fixed 20+4 pin and 8 pin cables without bending them sharply?

Mount the supply using the four screw holes on the 83.82 mm wide flange, route the fixed 20+4 pin main and 8 pin 12 V cables through the case cut-outs before securing the unit, and avoid sharp bends at the connector heads.

What maintenance will the 80 mm forced-air fan need over time?

The 80 mm fan draws air through the metal chassis; clean dust from the intake grill and fan blades every few months with compressed air to maintain airflow.

Which output limit appears first when the system draws continuous heavy load?

The +12 V rail is rated at 33 A; sustained loads near that level will reach the rail limit before the 500 W total rating is reached.