CyberPower
CyberPower PR2200LCDSL 2070VA 1980W 120V UPS
Sine-wave UPS with AVR delivers 2070 VA and 1980 W to seven NEMA outlets, providing 10 minutes runtime at half load and USB or serial management
- International Version120V
- Input Voltage Range75Vac - 154Vac +/- 3Vac
- Input Frequency57Hz - 63Hz +/- 1%
- Input ConnectionNEMA 5-20P
- VA Rating2070 VA
- Watts1980W
Options PR2200LCDSL
- PR750LCD
- PR1000LCD
- PR1500LCD
- PR1500LCDN
- PR2200LCDSL
- PR2200LCD
- PR3000LCDSL
- PR3000LCD
취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.
- Sine wave output protects sensitive equipment
- Automatic voltage regulation corrects fluctuations without battery use
- 2070 VA and 1980 W capacity supports demanding loads
- Seven NEMA outlets include one L5-20R and six 5-20R
- LCD panel shows real-time battery and power status
Smart App Sinewave UPS 2070 VA
The CyberPower PR2200LCDSL is a new mini-tower uninterruptible power supply rated at 2070 VA and 1980 W. It delivers pure sine-wave output at 120 V and uses Automatic Voltage Regulation to correct fluctuations between 75 V and 154 V without draining the battery. Seven outlets include one NEMA L5-20R and six NEMA 5-20R receptacles.
Server and network administrators
This unit suits managers of corporate servers, storage appliances, network gear and telecom equipment who need clean sine-wave power and AVR protection. The LCD panel shows real-time battery and power status while USB, serial and EPO ports link to PowerPanel Business Edition software. Buyers who require runtime beyond three minutes at full load or ten minutes at half load should consider other options.
Pure sine-wave output at 120 V
The waveform type is the single specification that decides suitability. Connected equipment that requires a true sine wave — such as active PFC power supplies and sensitive networking hardware — will operate correctly on battery. Devices that tolerate stepped or simulated sine-wave output do not need this feature.
주요 특징
- Sine wave output protects sensitive equipment
- Automatic voltage regulation corrects fluctuations without battery use
- 2070 VA and 1980 W capacity supports demanding loads
- Seven NEMA outlets include one L5-20R and six 5-20R
- LCD panel shows real-time battery and power status
사양
| Brand | CyberPower |
|---|---|
| Series | Smart App Sinewave |
| Model | PR2200LCDSL |
| International Version | 120V |
| Input Voltage Range | 75Vac - 154Vac +/- 3Vac |
| Input Frequency | 57Hz - 63Hz +/- 1% |
| Input Connection | NEMA 5-20P |
| VA Rating | 2070 VA |
| Watts | 1980W |
| Output Voltage | 120Vac +/- 5% |
| Output Frequency | 60Hz +/- 1% |
| Outlets | 7 |
| Outlet Type | NEMA L5-20R (1) & NEMA 5-20R (6) |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Runtime at Half Load (min): 10 Runtime at Full Load (min): 3 |
| Battery Recharge Time | 8 Hours |
| Battery Replaceable | RB1290X4F |
| Alarms | On Battery, Low Battery, Overload, Battery Missing, Fault |
| Interface Port | USB, Serial, and EPO Ports |
| Management Software | PowerPanel Business Edition |
| Surge Energy Rating | 1030 Joules |
| Protection | Internal circuitry limiting / circuit breaker |
| Features | 2070VA / 1980W Pure Sine Wave UPS Line-Interactive Topology Full AVR Buck/Boost & GreenPower UPS Mini-Tower Form Factor Multifunction LCD Panel SNMP/HTTP Remote Management Option 7 Outlets / USB, Serial, and EPO Ports EMI/RFI Filters PowerPanel Business Edition |
| Dimensions | 8.70" x 17.00" x 6.70" (H x W x D) |
| Weight | 51.9 lbs. |
| Package Contents | 88863V |
| 배송 무게 | 26.76 kg |
| 포장 크기 | 578 × 356 × 324 mm |
이 모델의 다른 버전
같은 라인업에서 3개 더
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
CyberPower PR1500LCDN UPS 1500VA/1500W 120V 8 Outlets
- 120 VAC
- 47 - 63 Hz
이 상품에 대한 질문
How do I connect the PR2200LCDSL to a 120 V circuit and which receptacle should I use for a 20 A device?
Plug the NEMA 5-20P input into a 120 V 20 A branch circuit; connect the 20 A load to the single NEMA L5-20R outlet and other equipment to the six NEMA 5-20R outlets.
Which replacement battery kit does this UPS take and how long does a recharge take?
The user-replaceable kit is RB1290X4F; after a full discharge the batteries reach full charge in 8 hours.
How long will the unit power my 1980 W load before the battery runs out?
At full 1980 W load the runtime is 3 minutes; at half load it extends to 10 minutes.