DELL
DELL PowerEdge R650 1U rack server 2x Xeon Gold 5317 3.0GHz 12C 512GB DDR4 H755 10x 1.8TB SAS
1U rack server with two 12-core Xeon Gold 5317 processors, 512 GB DDR4, H755 RAID, and ten 1.8 TB SAS drives
- TypeRack
- Rack Height1U
- Redundant Hot-swap PowerYes
- AI FeaturesNone
- CPU TypeIntel Xeon
- CPU Speed32
- Dual Xeon Gold 5317 12-core CPUs at 3.0 GHz base, 3.6 GHz turbo
- 512 GB DDR4 2933 MHz ECC memory across 16 modules
- PERC H755 RAID controller with 8 GB NV cache and battery backup
- 10 × 1.8 TB 10K SAS 12 Gb/s 2.5″ drives
- iDRAC9 Enterprise remote management plus dual 1400 W platinum PSUs
Dense 1U compute platform
The Dell PowerEdge R650 packs two Intel Xeon Gold 5317 processors, each with 12 cores at 3.0 GHz and a 3.6 GHz turbo, into a single rack unit. Sixteen 32 GB DDR4 modules provide 512 GB of registered ECC memory running at 2933 MHz. Ten 1.8 TB 10K SAS drives sit behind a PERC H755 controller with 8 GB NV cache and battery-backed write protection. Dual 1400 W platinum supplies and iDRAC9 Enterprise complete the package.
Virtualisation hosts and database clusters
This configuration suits teams that need high core density and large memory capacity in minimal rack space. The 10-drive bay layout and hardware RAID controller cover mixed read-write workloads with local redundancy. Organisations that require GPU acceleration, all-flash NVMe arrays, or single-thread frequency above 3.6 GHz should evaluate alternative platforms.
Ten 1.8 TB SAS drives on H755 RAID
The storage subsystem is the decisive factor: ten 2.5-inch 10K spindles deliver 18 TB raw capacity with hardware RAID 0, 1, 5, 6, 10, 50 and 60. Buyers who need more capacity per bay, silent solid-state media, or a different drive interface must look at other chassis or controller options.
주요 특징
- Dual Xeon Gold 5317 12-core CPUs at 3.0 GHz base, 3.6 GHz turbo
- 512 GB DDR4 2933 MHz ECC memory across 16 modules
- PERC H755 RAID controller with 8 GB NV cache and battery backup
- 10 × 1.8 TB 10K SAS 12 Gb/s 2.5″ drives
- iDRAC9 Enterprise remote management plus dual 1400 W platinum PSUs
사양
| Brand | DELL |
|---|---|
| Series | PowerEdge R650 |
| Model | R650 |
| Part Number | 3.00 GHz |
| Type | Rack |
| Rack Height | 1U |
| Redundant Hot-swap Power | Yes |
| AI Features | None |
| CPU Type | Intel Xeon |
| CPU Speed | 32 |
| CPU Socket | LGA 4189 |
| Number of CPU Cores | 12-Core Processor |
| # of Processors Installed | Gold 5317 |
| MAX Processors | 2 |
| Chipset | 0 |
| Installed Memory Size | 512GB |
| Memory Type | DDR4 |
| Max Memory Capacity | 2TB |
| Storage Controller | Dell Perc H755 Controller |
| HDD Interface | SAS |
| Raid Level | RAID 0/1/5/6/10/50/60 |
| Media Drives | 0 |
| GPU Type | Matrox G200 |
| Video Memory | 8MB |
| Ethernet Controller | Dell EMC 15G Broadcom 5720 Quad Port 1GbE OCP 3.0 Network Card |
| LAN Ports | 4 x Ports |
| Expansion Slots | 0 |
| Management Port | RJ 45 |
| Operating System | No |
| Features | 10 x 2.5" SATA/SAS Hot-Plug Drive Bays |
이 상품에 대한 질문
What RAID levels does the PERC H755 controller support with its 8GB NV cache?
The PERC H755 controller supports RAID 0, 1, 5, 6, 10, 50 and 60 with 8GB of non-volatile cache and a battery backup.
What physical space and rails are required to mount this 1U server?
The server occupies 1U of rack height and includes Dell Ready Rails for installation in standard four-post racks.
How are the 10 SAS drives installed and what step is often missed?
The 2.5-inch drives slide into the front hot-swap bays; the common error is not seating each carrier until the latch clicks, which leaves the SAS connection loose.
이 진열대의 다른 상품
고객들이 함께 비교한 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
Higole 11.6" Touch All-in-One PC Celeron N5095 8GB 128GB
- 11.6"
- 1366 x 768
Toemaagic All-in-One PC 24" FHD i7 4.0GHz 16GB 512GB White
- Toemaagic
- 16 GB
Lenovo A100 23.8" FHD All-in-One PC Intel N100 32GB DDR4 2TB SSD 1TB Dock Windows 11 Pro White
- All-in-One PC
- All-in-One



