저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

DELL

DELL PowerEdge R730 2U rack server 2× E5-2630 v3 2.4GHz 16GB DDR4 2× 900GB SAS H330

SKU CH-DESX-79JKB

2U rack server with dual eight-core Xeon processors at 2.4GHz, 16GB DDR4, two 900GB 10K SAS drives and an H330 RAID controller supporting RAID 0, 1, 5, 10, 50 and 60

  • TypeRack
  • Rack Height2U
  • Redundant Hot-swap PowerYes
  • CPU TypeDual Intel Xeon
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 16GB

HDD 2 x 900GB

  • Dual Xeon E5-2630 v3 CPUs deliver 16 cores and 32 threads for parallel workloads
  • 16GB DDR4 memory installed across 24 DIMM slots for future expansion
  • Two 900GB 10K SAS drives provide fast hot-plug storage in 2.5-inch bays
  • H330 12Gbps RAID controller supports RAID 0 1 5 10 50 60 for data protection
  • Dual 750W redundant power supplies keep the 2U rack server running during a failure

Dual Xeon E5-2630 v3 server for virtualisation

The Dell PowerEdge R730 is a 2U rack server fitted with two eight-core Intel Xeon E5-2630 v3 processors at 2.4GHz. Sixteen gigabytes of DDR4 memory and two 900GB 10K SAS drives on a PERC H330 RAID controller provide a ready-to-run platform for virtualisation hosts, database nodes or application servers. Dual 750W redundant power supplies and hot-plug drive bays support continuous operation in small-to-medium data-centre deployments.

Redundant cooling and power in a 2U chassis

Dual 750W hot-swap power supplies share the load, so a single failure does not interrupt service. The 2U form factor directs front-to-rear airflow across the processors, memory and drive cage, keeping component temperatures stable during normal multi-tenant workloads. Acoustic output remains within typical rack-environment limits when the system idles or serves light traffic.

Sustained load behaviour with 32 logical cores

Under continuous compute pressure all 32 logical threads remain active while the H330 controller manages RAID 0, 1, 5, 10, 50 or 60 across up to eight 2.5-inch bays. Memory bandwidth scales to 2400MT/s per DIMM within the 16GB installed limit, and the four-port 1GbE daughter card handles steady network streams. Expansion headroom includes seven PCIe 3.0 slots and a dedicated PERC slot for additional controllers.

주요 특징

  • Dual Xeon E5-2630 v3 CPUs deliver 16 cores and 32 threads for parallel workloads
  • 16GB DDR4 memory installed across 24 DIMM slots for future expansion
  • Two 900GB 10K SAS drives provide fast hot-plug storage in 2.5-inch bays
  • H330 12Gbps RAID controller supports RAID 0 1 5 10 50 60 for data protection
  • Dual 750W redundant power supplies keep the 2U rack server running during a failure

사양

BrandDELL
SeriesPowerEdge
ModelPowerEdge R730
TypeRack
Rack Height2U
Redundant Hot-swap PowerYes
CPU TypeDual Intel Xeon
MAX Processors2
ChipsetIntel C610
Installed Memory Size16GB
Memory TypeDDR4
Max Memory Capacity16GB
Memory Features24 DIMM slots, 12 per processor. (4GB/8GB/16GB/32GB/64GB/128GB DDR4 up to 2400MT/s, actual memory speed dependent on the processor capability)
Number of Memory Slots24
Storage ControllerDell Perc H330 Controller
HDD InterfaceSAS
SSD (Installed)No
Raid LevelRAID 0/1/5/10/50/60
Max HDD Capacity64TB
Media DrivesDVD ROM
GPU TypeMatrox G200
Video Memory8MB
Remote ManagementiDRAC8 with Lifecycle Controller, iDRAC8 Express (default), iDRAC8 Enterprise (upgrade) 8GB vFlash media (upgrade), 16GB vFlash media (upgrade)
LAN Ports4 x Ports
Expansion SlotsUp to 7 x PCIe 3.0 plus dedicated PERC slot
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight70.0000LBS

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How do I install the 2× 900 GB SAS drives into the 8-bay 2.5-inch hot-plug chassis?

Slide each drive into an empty bay until the latch clicks, then configure the desired RAID level in the H330 controller BIOS before the OS loads.

What maintenance will the dual 750 W redundant power supplies need over time?

Keep the intake filters clean and verify both units show green LEDs; a failed module can be hot-swapped without shutting down the server.

Which limit appears first when the two E5-2630 v3 CPUs run sustained workloads?

The installed 16 GB DDR4 across 24 DIMM slots caps memory capacity at 16 GB, so memory pressure arrives before CPU thermal limits.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.