DELL PowerEdge R930 4U rack server 4x Xeon 2.4GHz 16-core 3TB DDR4 24x 1.8TB SAS
- 4U
- Intel Xeon
DELL
Four-socket 4U rack server with 96 cores at 2.2 GHz, 3 TB DDR4 ECC memory, H730P RAID controller, and four 600 GB 10K SAS drives
The Dell PowerEdge R930 is a 4U rack server built for enterprise workloads that demand maximum core count and memory capacity in a single chassis. Four Intel Xeon E7-8890 v4 processors deliver 96 cores at 2.2 GHz with 3.4 GHz turbo frequency for heavily threaded applications.
Four hot-plug 1100 watt 80+ Platinum power supplies provide N+N redundancy for continuous operation under full load. The 4U form factor accommodates extensive internal airflow paths across 96 DDR4 DIMM slots and 24 drive bays while maintaining stable thermals.
Embedded iDRAC8 Enterprise enables agent-free remote management, lifecycle automation and virtual console access from any location. The Intel X520/I350 daughter card adds two 10 Gb SFP+ and two 1 GbE ports for flexible fabric connectivity without consuming PCIe slots.
| Brand | DELL |
|---|---|
| Series | PowerEdge R930 |
| Rack Height | 4U |
| CPU Type | Intel Xeon |
| CPU Speed | 2.20 GHz |
| CPU Socket | LGA 2011 |
| Number of CPU Cores | 24-Core Processor |
| # of Processors Installed | 4 |
| MAX Processors | 4 |
| Chipset | Intel C602J |
| Installed Memory Size | 3TB |
| Memory Type | DDR4 |
| Max Memory Capacity | 12TB |
| Number of Memory Slots | 96 |
| Storage Controller | Dell Perc H730P 2GB Controller |
| HDD Interface | SAS |
| SSD (Installed) | No |
| Raid Level | RAID 0/1/5/6/10/50/60 |
| GPU Type | Matrox G200 |
| Video Memory | 8MB |
| Ethernet Controller | Dell Intel X520/I350 Quad Port 2x 1GbE 2x 10Gb SFP+ Network Daughter Card |
| LAN Ports | 4 x Ports |
| Expansion Slots | 1 x PCIe 3.0 x16 Slot, Single Riser Included (Riser 3) |
| Management Port | RJ 45 |
| Operating System | No |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
Align each processor with the socket keying, lower the load plate gently, and torque the retention screws in the prescribed sequence; the step often missed is applying the correct thermal interface material thickness for the 2.2 GHz 24-core dies before seating the heatsinks.
The controller battery typically requires replacement every three to five years to preserve RAID cache during power loss, while the four 1100W PSUs should be inspected for fan wear and capacitor aging after extended 24/7 operation.
Memory bandwidth and thermal headroom become the bottleneck; the 2400 MHz DDR4 channels and the 4U cooling capacity constrain sustained turbo before the 12 TB maximum capacity is reached.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?