저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

HP

HP ProLiant DL370 G6 Xeon X5650 2P 12GB P410i 8SFF rack server

SKU CH-KV8R-H5AD7

Dual Xeon X5650 2.66 GHz 6-core CPUs, 12 GB DDR3-1333 across 18 slots, P410i with 1 GB FBWC, eight 2.5-inch hot-plug bays, redundant 750 W supplies in 4U rack form

  • TypeRack
  • Dual Xeon X5650 processors deliver 12 cores at 2.66 GHz
  • 12 GB DDR3-1333 memory expands to 192 GB across 18 DIMM slots
  • Smart Array P410i with 1 GB FBWC accelerates RAID performance
  • Four 1 GbE ports on NC375i controller provide flexible network connectivity
  • Dual 750 W redundant hot-plug power supplies maintain uptime

HP ProLiant DL370 G6 dual-Xeon server

This 4U rack server delivers two-socket compute power in a chassis built for enterprise virtualization and consolidation workloads. It ships with two Intel Xeon X5650 processors and 12 GB of registered DDR3 memory, ready for deployment in growing businesses or data-centre environments.

Thermal and power profile

Two 750 W high-efficiency redundant hot-plug supplies share the load, keeping the system running if one unit fails. Each X5650 processor draws 95 W, so the platform is designed to handle the combined thermal output of twelve cores at 2.66 GHz under typical virtualization demand.

Storage controller and drive support

A Smart Array P410i with 1 GB flash-backed write cache manages the eight 2.5-inch hot-plug bays, accepting SAS or SATA drives. The controller is the deciding factor for buyers who need hardware RAID with battery-backed cache; those requiring more than eight bays or a different RAID engine should look elsewhere.

주요 특징

  • Dual Xeon X5650 processors deliver 12 cores at 2.66 GHz
  • 12 GB DDR3-1333 memory expands to 192 GB across 18 DIMM slots
  • Smart Array P410i with 1 GB FBWC accelerates RAID performance
  • Four 1 GbE ports on NC375i controller provide flexible network connectivity
  • Dual 750 W redundant hot-plug power supplies maintain uptime

사양

TypeRack

이 상품에 대한 질문

How is the Smart Array P410i controller with 1GB FBWC installed and which step is often missed?

The P410i is integrated on the system board; the step often missed is inserting the 1GB flash-backed write cache module into its dedicated socket and enabling it in the BIOS before creating arrays.

What maintenance or replacement will the 1GB FBWC on the P410i need later?

The flash-backed write cache uses a super-capacitor pack that typically requires replacement after several years of continuous operation to maintain data protection during power loss.

What limit appears first on the 750W redundant power supplies under sustained full load?

The dual 750W hot-plug supplies share the load; the first limit reached is the combined 750W output capacity if both processors and all drive bays draw maximum power simultaneously.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.