Online UPS delivers true sine-wave power at 3000 VA and 2700 W with lithium batteries that recharge to full capacity in two hours
Model END3000RT2U-LNC
The Minuteman END3000RT2U-LNC is a true sine wave online UPS rated at 3000VA and 2700W with a 0.9 power factor. It operates on 120V input with a wide range of 55VAC to 160VAC and supports frequencies from 40Hz to 70Hz. The unit installs in either rack or tower orientation for flexible deployment.
The UPS uses LIFE-247500 lithium batteries that recharge to full capacity in two hours at a 4A charging current. Online double conversion topology continuously conditions power, delivering stable output voltage across 100V to 127V settings regardless of input fluctuations. This architecture sustains connected loads through extended outages without transfer delay.
Output receptacles include 5-15/20R and L5-30R interfaces, defining the maximum plug types and current ratings the unit can directly support. The 120V international version restricts use to compatible regional grids. Buyers needing higher voltage outputs or different connector standards cannot use this model.
| Brand | MINUTEMAN |
|---|---|
| Model | END3000RT2U-LNC |
| International Version | 120V |
| Input Voltage Range | 55VAC-160VAC +/- 5 % ( Load Dependent) |
| Input Frequency | 40Hz ~ 70 Hz |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 100/110/115/120/125/127 VAC |
| Output Frequency | 47 ~ 53 Hz or 57 ~ 63 Hz |
| Battery Type | LIFE-247500 |
| Battery Recharge Time | 2 hours recover to 100% capacity @ 4A charging current |
| Humidity | 20-95 % RH @ 0- 40°C (non-condensing) |
| Dimensions | 24.8" x 17.2" x 3.5" |
| Weight | 45.2 lbs. |
| 배송 무게 | 19.41 kg |
| 포장 크기 | 511 × 437 × 86 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
The unit uses a true sine-wave online topology that keeps the inverter active at all times, so internal fans run continuously to cool the lithium battery pack and power stage; expect a steady airflow noise typical of 2U rack equipment.
The UPS requires a NEMA L5-30R receptacle fed by a 30 A, 120 V circuit; the 55 VAC–160 VAC input range tolerates sags but the branch circuit must supply the locking connector.
Yes, the selectable output voltage includes 115 VAC, so older 115 V equipment can be plugged directly into the controllable 5-15/20R outlets without an extra transformer.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?