저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

OEM Industries

OEM Industries MMF-06D24DS FC5 60mm 3-pin CPU cooler

SKU CH-082X-AETRX

A 60 mm ball-bearing fan with a 3-pin connector runs at 24 V for server and inverter cooling

  • ColorBlack
  • TypeFan only
  • Fan Size60mm
  • Bearing TypeBall
  • Power Connector3 Pin
  • LEDNo
  • 60 mm frame fits compact server chassis
  • 24 V 0.09 A draw keeps power use low
  • Ball bearing design extends operating life
  • Three-pin connector enables speed monitoring
  • Black finish suits industrial equipment aesthetics

60 mm 24 V server fan

This 60 mm frame fan runs on 24 V and draws 0.09 A through a three-pin connector. It is built for inverter and server environments such as ABB, Fanuc and Yaskawa equipment where a compact axial flow is required.

Replaces worn 6025 units

The MMF-06D24DS FC5 matches the 6025 footprint and three-wire interface so it can slot into existing brackets without rewiring. The jump is worth it when the original ball-bearing fan has become noisy or has failed completely.

Fits tight 60 mm bays

The 60 by 25 mm profile leaves clearance for dense rack chassis and industrial enclosures. Ball bearings and the absence of LEDs keep the unit suitable for continuous duty in headless server rooms.

주요 특징

  • 60 mm frame fits compact server chassis
  • 24 V 0.09 A draw keeps power use low
  • Ball bearing design extends operating life
  • Three-pin connector enables speed monitoring
  • Black finish suits industrial equipment aesthetics

사양

ModelMMF-06D24DS FC5
ColorBlack
TypeFan only
Fan Size60mm
Bearing TypeBall
Power Connector3 Pin
LEDNo

이 상품에 대한 질문

Will the 60mm by 25mm frame fit my server bracket?

The fan measures 60mm square and 25mm thick, matching the standard 6025 mounting pattern used on many inverter and server chassis.

How do I connect the three-pin lead to a 24V supply?

Plug the 3-pin connector into a 24V header rated for at least 0.09A; the third wire carries the tach signal so the controller can monitor speed.

When should I plan to replace the ball-bearing fan?

Ball bearings typically run for years in continuous 24V operation; replace the unit once bearing noise appears or RPM drops below spec.