저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Other Electricities

Other Electricities 150M LC-LC SM 4 Strand Armored Field TPU Optic Patch Cable Waterproof Head

SKU CH-DVYC-0NB9C

A 150-metre armored single-mode patch cable with four LC/UPC fibres, TPU jacket, and waterproof heads for harsh indoor or outdoor deployments

  • TypeRack
  • OS2 singlemode supports long-distance links at 1310/1550nm
  • Armored TPU jacket resists crush 1000/3000 N and 200 impacts
  • Four LC/UPC fibers with .3 dB insertion loss and 50 dB return loss
  • Tight 10D static and 20D dynamic bend radii suit field deployment
  • 150 m length with 200/600 N tensile rating for rapid retrieval

Tactical Fiber Cable

This 150 metre armored patch cable carries four OS2 singlemode fibers terminated with LC UPC connectors. It is built for rapid deployment in military or field environments where repeated retrieval and harsh handling are routine.

Build Integration

The TPU jacket resists oil, flame, abrasion and crushing forces up to 3000 N short term. A minimum dynamic bend radius of 20D and static radius of 10D frees routing inside tight conduits or around corners without signal loss.

Upgrade Path

It replaces standard indoor patch cords that cannot survive direct burial, vehicle traffic or repeated flex cycles exceeding 2000 bends. The jump is worth it when the link must cross building boundaries, underground ducts or tactical zones where ordinary cables fail.

주요 특징

  • OS2 singlemode supports long-distance links at 1310/1550nm
  • Armored TPU jacket resists crush 1000/3000 N and 200 impacts
  • Four LC/UPC fibers with .3 dB insertion loss and 50 dB return loss
  • Tight 10D static and 20D dynamic bend radii suit field deployment
  • 150 m length with 200/600 N tensile rating for rapid retrieval

사양

TypeRack

이 상품에 대한 질문

What is the minimum dynamic bend radius before signal loss increases on this 150 m armored cable?

The minimum dynamic bend radius is 20D (mm) and the minimum static bend radius is 10D (mm) for the G.657.A1 fiber grade.

How much insertion loss and return loss should I expect from the LC UPC connectors after a full day of operation?

Insertion loss is .3 dB for LC connectors; return loss is 50 dB for UPC polish.

What tensile load can the TPU jacket withstand during repeated field deployment and retrieval?

The cable supports a long-term tensile load of 200 N and a short-term tensile load of 600 N.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.