Tripp Lite
Tripp Lite AVR700U 700VA 350W Line-Interactive UPS
Line-interactive UPS delivers 700 VA with automatic voltage regulation from 83 to 147 V, four battery-backed and four surge-only outlets, USB monitoring and TEL/DSL protection
- Input Voltage Range120V AC
- Input ConnectionNEMA 5-15P
- VA Rating700 VA
- Watts350 Watts
- Output Voltage115V (+/- 5%)
- Outlets8 5-15R
VA 700 VA
- 550 VA
- 700 VA
- 750 VA
- 900 VA
- 450 VA Tower
- 650 VA Tower
취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.
- Automatic voltage regulation corrects brownouts and overvoltages from 83V to 147V
- Four battery-backed outlets keep critical equipment running during outages
- Four surge-only outlets protect peripherals from damaging spikes
- USB port enables monitoring and graceful shutdown via PowerAlert software
- Compact 3.50" x 11.30" x 6.00" design fits desktop or wall mounting
Compact line-interactive UPS for desktop equipment
The Tripp Lite AVR700U is a 700 VA, 350 W line-interactive uninterruptible power supply that corrects brownouts and overvoltages from 83 V to 147 V without using battery power. It provides 115 V output at up to 98 percent efficiency and includes a USB port for PowerAlert management software. The unit mounts on a desktop or wall and ships new.
Suits workstations needing brief ride-through
Four NEMA 5-15R outlets supply battery-backed power while four additional outlets provide surge-only protection plus a single TEL/DSL line guard. At half load the internal VRLA battery delivers 8.6 minutes of run time and recharges from 10 percent to 90 percent in about 12 hours. Buyers who need longer backup durations or higher wattage capacity should look at larger units.
350 W continuous output rating determines the load
The 350 watt rating is the single figure that decides whether connected equipment stays powered during an outage. Exceeding this limit triggers overload alarms and forces the UPS onto bypass, so total attached draw must remain at or below 350 W. All other specifications follow from this power ceiling.
주요 특징
- Automatic voltage regulation corrects brownouts and overvoltages from 83V to 147V
- Four battery-backed outlets keep critical equipment running during outages
- Four surge-only outlets protect peripherals from damaging spikes
- USB port enables monitoring and graceful shutdown via PowerAlert software
- Compact 3.50" x 11.30" x 6.00" design fits desktop or wall mounting
사양
| Brand | TRIPP LITE |
|---|---|
| Model | AVR700U |
| Input Voltage Range | 120V AC |
| Input Connection | NEMA 5-15P |
| VA Rating | 700 VA |
| Watts | 350 Watts |
| Output Voltage | 115V (+/- 5%) |
| Outlets | 8 5-15R |
| Outlet Type | 4 UPS outlets, 4 surge-only outlets |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half Load Runtime: 8.6 minutes (175 Watts) |
| Battery Recharge Time | 12 hours (10% to 90%) |
| Alarms | Audible alarm indicates power-failure and overload status |
| Interface Port | USB |
| Management Software | PowerAlert |
| Data Line Protection | 1 line TEL/DSL (1 in / 1 out) |
| Surge Energy Rating | 420 Joules |
| Features | 700VA ultra-compact 120V line interactive UPS Corrects brownouts and overvoltages from 83V to 147V 4 UPS battery supported outlets, 4 surge-only outlets USB port, TEL/DSL protection, Wall mountable, 98% efficient NEMA 5-15P input plug and 8 NEMA 5-15R outlets |
| Dimensions | 3.50" x 11.30" x 6.00" |
| Weight | 11.00 lbs. |
| Package Contents | AVR700U UPS System USB cable Instruction manual |
| VA | 700 VA |
| 배송 무게 | 5.15 kg |
| 포장 크기 | 345 × 221 × 124 mm |
이 상품에 대한 질문
How do I mount the AVR700U on a wall without blocking the USB or TEL/DSL ports?
Use the keyhole slots on the rear chassis; keep at least 50 mm clearance above the unit so the USB cable and the RJ-11 pass-through can be inserted and removed without strain.
When will the internal VRLA battery need replacement, and what is the correct part?
Expect 3 to 5 years of service; replace with a 12 V, 7 Ah VRLA pack (typically RBC2-compatible) and recharge for 12 hours from 10 % to 90 % before returning to duty.
At what load does the 8.6-minute runtime apply, and what happens if I exceed 350 W?
The 8.6-minute figure is at 175 W half load; drawing more than 350 W triggers the audible overload alarm and the UPS will shut down to protect the inverter.
이 진열대의 다른 상품
고객들이 함께 비교한 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear



