저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Tripp Lite

Tripp Lite PDUH20HVL6 PDU 20A 208/240V 14 Outlets 12 C13 2 C19 L6-20P 15ft 1U

SKU CH-2KR7-YFQX7 MPN PDUH20HVL6

A 1U rackmount PDU distributing 208/240 V power through 12 C13 and 2 C19 outlets from a 20 A L6-20P input with a 15 ft cord

  • TypeBasic
  • StyleRackmount
  • CertificationsTested to UL 60950 (USA), CSA (Canada), RoHS Compliant
  • ROHSYes
  • Package IncludesPDUH20HVL6 3.3 / 3.8kW Single-Phase 208 / 240 V Basic PDU Mo
  • Input Voltage200; 208; 240 V
  • 20 A 208/240 V input delivers up to 3.8 kW
  • 14 outlets — 12 C13 and 2 C19 — fit dense server racks
  • 15 ft L6-20P cord reaches distant power panels
  • 1U rackmount with detachable flanges also mounts 0U, wall or under-counter
  • Switchless design prevents accidental shutdowns
  • Tested to UL 60950 and CSA, RoHS compliant

20A 208/240V 1U rack PDU

The Tripp Lite PDUH20HVL6 is a basic power distribution unit rated for 20A at 200, 208 or 240 V input. It provides 14 IEC outlets — 12 C13 and 2 C19 — for servers, switches and networking gear. The unit supports 3.3 kW at 208 V or 3.8 kW at 240 V single-phase loads. It is built for 1U horizontal rack mounting in standard 19-inch enclosures.

All-metal case with detachable flanges

A rugged metal housing includes a reversible chassis and detachable mounting flanges that allow 1U horizontal, 0U vertical, wall or under-counter installation. The 15 ft cord terminates in a NEMA L6-20P locking plug for secure inlet connection. Twelve C13 outlets are split between front and rear faces, while two C19 outlets sit at the rear for higher-draw devices. A switchless design prevents accidental power-off, and a rear grounding lug is provided.

Replaces basic strip PDUs in dense racks

This unit upgrades from unmanaged power strips by adding locking input, IEC outlet mix and flexible mounting in a 1U profile. The jump is worth it when you need both C13 and C19 receptacles, a 20A circuit with 16A continuous rating, and the ability to orient the cord entry front or rear. It is not suited for environments requiring metered or switched outlet control.

주요 특징

  • 20 A 208/240 V input delivers up to 3.8 kW
  • 14 outlets — 12 C13 and 2 C19 — fit dense server racks
  • 15 ft L6-20P cord reaches distant power panels
  • 1U rackmount with detachable flanges also mounts 0U, wall or under-counter
  • Switchless design prevents accidental shutdowns
  • Tested to UL 60950 and CSA, RoHS compliant

사양

BrandTripp Lite
ModelPDUH20HVL6
TypeBasic
StyleRackmount
CertificationsTested to UL 60950 (USA), CSA (Canada), RoHS Compliant
ROHSYes
Package IncludesPDUH20HVL6 3.3 / 3.8kW Single-Phase 208 / 240 V Basic PDU
Mounting hardware
Owner's manual
Input Voltage200; 208; 240 V
Maximum Input Current20A
Input Connector(s)NEMA L6-20P
Cord Length15 ft
Output Voltage200; 208; 240 V
Output Frequency50/60Hz
Output Connector(s)2 C19, 12 C13
Dimensions1.75" x 17.25" x 3.75"
Weight3.75 lbs.
배송 무게3.01 kg
포장 크기635 × 356 × 356 mm

이 상품에 대한 질문

What input plug does the PDUH20HVL6 use and what current does it support?

The PDUH20HVL6 uses a NEMA L6-20P input plug and supports a maximum input current of 20A, agency de-rated to 16A continuous.

What rack space and mounting options does the PDUH20HVL6 require?

It fits 1U horizontal 19-inch rackmount and, with detachable flanges, 0U vertical, wallmount or under-counter installation.

How is the PDUH20HVL6 installed and which step is often missed?

Attach the included mounting flanges for horizontal or vertical orientation, then secure the grounding lug on the back panel before powering on.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.