저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Tripp Lite

Tripp Lite PDUMH20-6 Metered PDU 120V 20A 12 Outlets 6ft

SKU CH-R2AQ-2S5WF MPN PDUMH20-6

A metered rackmount PDU distributes 120 V power to twelve outlets while a built-in LED meter displays real-time load in amps

  • TypeMetered
  • Front Panel LEDsTwo digit current meter reports output load in amps
  • CertificationsTested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (
  • ROHSYes
  • Input Voltage100V; 120V; 127V
  • Maximum Input Current20A
  • Built-in 2-digit amp meter shows live load at a glance
  • 12 NEMA 5-15/20R outlets distribute power to rack equipment
  • 20 A single-phase input with L5-20P plug supports high-density 120 V deployments
  • 6 ft attached cord reaches rack power without extension leads
  • UL 60950-1 and CSA C22.2 No. 60950-1 tested for North American safety compliance

Metered 12-outlet 120V PDU

The Tripp Lite PDUMH20-6 is a 1U rackmount power distribution unit with twelve 5-15/20R outlets and a built-in two-digit ammeter that continuously shows the total load in amps. It accepts 100-127V single-phase input through a six-foot cord ending in a NEMA L5-20P plug and is tested to UL 60950-1 and CSA C22.2 No. 60950-1-03.

Upgrade from basic unmetered strips

Replacing a simple power strip with this metered PDU lets administrators see real-time current draw so circuits stay below the 16A continuous de-rating and the 20A overload protection threshold. The jump is worth it when equipment additions make blind power budgeting risky or when audit requirements demand visible load verification at the rack.

Sustained load visibility at 16A continuous

Under continuous operation the meter updates constantly, giving immediate feedback as servers, switches or storage arrays cycle through peak and idle states. The 20A breaker protects the branch circuit while the 5-95% humidity and 0-3000m elevation ratings confirm the unit tolerates typical data-centre environments without derating beyond the agency-specified 16A continuous limit.

주요 특징

  • Built-in 2-digit amp meter shows live load at a glance
  • 12 NEMA 5-15/20R outlets distribute power to rack equipment
  • 20 A single-phase input with L5-20P plug supports high-density 120 V deployments
  • 6 ft attached cord reaches rack power without extension leads
  • UL 60950-1 and CSA C22.2 No. 60950-1 tested for North American safety compliance

사양

BrandTripp Lite
ModelPDUMH20-6
TypeMetered
Front Panel LEDsTwo digit current meter reports output load in amps
CertificationsTested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada)
ROHSYes
Input Voltage100V; 120V; 127V
Maximum Input Current20A
Input Connector(s)NEMA 5-20P; NEMA L5-20P
Cord Length6 ft
Output Voltage100-127V nominal, single phase
Output Frequency50/60Hz
Output Connector(s)(12) 5-15/20R
Overload Protection20A
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-15 to 50 ºC
Features20A single phase 120V Metered Power Distribution Unit / PDU (Agency de-rated to 16A continuous)
Built-in 2 digit visual meter continuously reports PDU load level in amps
Attached NEMA L5-20P 20A 120V input plug with 6 ft. / 1.8m line cord
Includes 5-20P 20A 120V plug adapter
1U horizontal rackmount format installs in one rack space
12 NEMA 5-15/20R outlets
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Optional PDUSID
Dimensions1.75 x 17.50" x 3.75" (H x W x D)
Weight4.60 lbs.
배송 무게2.27 kg
포장 크기511 × 239 × 56 mm

이 상품에 대한 질문

What rack width and height does the 17.50 x 1.75 inch PDU require?

The unit is 17.50 inches wide and 1.75 inches high, matching a 1U rack-mount space.

How do I connect the 6 ft cord with its NEMA L5-20P plug, and what step is often missed?

Plug the attached NEMA L5-20P connector into a 20A 120V receptacle; the step often missed is confirming the branch circuit is rated for 20A continuous (de-rated to 16A).

When should the internal 20A overload protection be checked or the unit replaced?

Inspect after any overload trip; replace if the two-digit meter reads inaccurately or if the housing shows heat damage.