저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Tripp Lite

Tripp Lite PDUMH30NET Switched PDU 2.9 kW 120V 16 Outlets L5-30P 10ft 2U

SKU CH-AVN8-CTEB2 MPN PDUMH30NET

Switched 2.9 kW 120V PDU with 16 individually controlled outlets, network monitoring and L5-30P input

  • TypeSwitched
  • Rack Size2U
  • StyleRackmount
  • Front Panel LEDs16 power availability LEDs confirm power off/on status for e
  • CertificationsTested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM
  • ROHSYes
  • Remotely reboot unresponsive hardware via web interface
  • 16 switched outlets with cord retention prevent accidental disconnects
  • 2U rackmount fits standard cabinets with reversible housing
  • Network monitoring reports voltage, frequency and load level locally and remotely
  • TAA-compliant for government and regulated-sector deployments

Switched 30A 120V PDU

This Tripp Lite PDU distributes 120V single-phase power through sixteen NEMA 5-15/20R outlets in a 2U horizontal rackmount chassis. A NEMA L5-30P plug on a ten-foot cord connects the unit to a 30A branch circuit. The switched design allows remote on, off, and reboot control for each outlet via a built-in web interface.

Suited for managed rack rows, not basic power strips

Network administrators who need outlet-level switching, power sequencing, and load-shedding to protect critical servers will use these features daily. The ethernet interface supports secure web, SNMP, and Telnet access for remote management. Sites that only need unmanaged power distribution or lack network connectivity at the rack will not benefit from the switched functions.

24A continuous derated capacity

The agency-derated input current of 24A continuous sets the usable load limit for connected equipment. Two front-panel LEDs with a toggle button show real-time current for bank 1, bank 2, or both banks combined. Sixteen power-availability LEDs confirm the on/off state of every outlet at a glance.

주요 특징

  • Remotely reboot unresponsive hardware via web interface
  • 16 switched outlets with cord retention prevent accidental disconnects
  • 2U rackmount fits standard cabinets with reversible housing
  • Network monitoring reports voltage, frequency and load level locally and remotely
  • TAA-compliant for government and regulated-sector deployments

사양

BrandTripp Lite
ModelPDUMH30NET
TypeSwitched
Rack Size2U
StyleRackmount
Front Panel LEDs16 power availability LEDs confirm power off/on status for each built-in outlet. Two additional LEDs with toggle button identify which bank the visual current meter is reporting (bank 1, bank 2 or bank 1&2 combined)
CertificationsTested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico)
ROHSYes
Input Voltage120V
Maximum Input Current30A
Regulatory Derated Input Current24A
Cord Length10 Feet
Output Voltage120V
Output Frequency50/60Hz
Operating Relative Humidity0-95% non-condensing
Features30A 120V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous)
Attached L5-30P 120V single phase input, 10 Feet input cord
2U horizontal rackmount form factor
16 NEMA 5-15/20R switched outlets
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on / power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage and total output load level in amps
Digita
Dimensions3.5" x 17.5" x 12.5"
Weight13.8 lbs.
배송 무게8.62 kg
포장 크기521 × 432 × 203 mm

이 상품에 대한 질문

How do I install the PDUMH30NET and what step is often missed?

Mount the 2U unit in a standard rack, connect the attached 10-foot NEMA L5-30P cord to a 30 A branch circuit, then configure the network settings via web, SNMP or Telnet before powering on outlets.

What maintenance or replacement will the PDUMH30NET need later?

The unit has no user-replaceable parts; periodically verify the 24 A derated load stays within limits, check that the 16 outlet retention brackets remain secure, and confirm environmental sensors report 0-95 % non-condensing humidity.

What limit appears first during sustained use of the PDUMH30NET?

The regulatory derated input current of 24 A continuous is the first limit; the visual current meter and network alarms warn before the 30 A branch breaker trips.