Tripp Lite SU750RTXLCD2U 750VA 675W 120V UPS
- 120V
- NEMA 5-15P
Tripp Lite
Double-conversion UPS delivers 1.5kVA / 1350W sine-wave output with hot-swap batteries, six NEMA 5-15R outlets and USB/DB9/EPO management in a 2U rack/tower chassis
VA 1500 VA
The Tripp Lite SmartOnline SU1500RTXLCD2U is a 1.5kVA double-conversion UPS designed for rack or tower deployment in 2U spaces. It delivers pure sine-wave output at 1350 watts to shield servers, network gear and medical equipment from every power anomaly.
Incoming AC is rectified to DC and regenerated as clean 120V 50/60Hz power, providing zero transfer time during outages. The unit accepts 100V through 127V input and supplies six NEMA 5-15R outlets split across two independently switched load banks.
Hot-swappable VRLA batteries give 4.2 minutes at full load or 14 minutes at half load, with optional BP48V27-2US packs adding extended run time. A USB HID port, DB9 serial, contact closure, EPO and an SNMP card slot enable PowerAlert software monitoring and remote shutdown.
| Brand | TRIPP LITE |
|---|---|
| Series | SMARTONLINE |
| Model | SU1500RTXLCD2U |
| Input Voltage Range | 100V AC; 110V AC; 115V AC; 120V AC; 127V AC |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 1350 Watts |
| Output Voltage | 100V; 110V; 115V; 120V; 127V |
| Output Frequency | 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
| Outlets | 6 |
| Outlet Type | 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load Runtime: 4.2 minutes (1350 Watts) Half Load Runtime: 14 minutes (675 Watts) |
| Battery Recharge Time | Less than 3 hours recharge to 90%; Add 6 hours per BP48V27-2US (typical, full load discharge) |
| Battery Replaceable | RBC94-2U |
| Alarms | Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
| Interface Port | USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
| Management Software | PowerAlert |
| Approvals | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances); ENERGY STAR Qualified |
| Rackmountable | 2U |
| Data Line Protection | 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
| Surge Energy Rating | 570 Joules |
| Features | Tripp Lite SU1500RTXLCD2U 1500 VA / 1.5 kVA / 1350 Watts on-line, double-conversion 2U rack / tower UPS Selectable 100 / 110 / 120 / 127V output (120V factory preset) NEMA 5-15P input, 6 NEMA 5-15R outlets Two switched 3-outlet load banks support remote reboot or programmable load shedding options Supports 2% output voltage regulation and zero transfer time in double conversion mode Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions 14 minutes runtime at 50% load (675 Watts) and 4.2 minutes at 100% load (1350 Watts) with internal batteri |
| Dimensions | 3.50" x 17.50" x 18.50" |
| Weight | 45.20 lbs. |
| Package Contents | SU1500RTXLCD2U UPS System PowerAlert Software with USB, Serial & EPO cabling 4 post rackmount installation kit Instruction manual |
| 배송 무게 | 26.35 kg |
| 포장 크기 | 594 × 513 × 224 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
At full load the internal battery delivers 4.2 minutes; at half load (675W) it provides 14 minutes.
It isolates connected gear from line disturbances and lets the UPS accept 50Hz or 60Hz input while delivering a regulated sine-wave output at the same or the other frequency.
The unit is 18.5in deep and includes both rack-mount ears for a standard 2U slot and tower feet for desktop placement.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.