A 1000VA/1000W double-conversion UPS with a 1.0 output power factor, six NEMA 5-15R outlets, an included network management card, and Energy Star 2.0 certification
Option GXT5-1000LVRT2UXLTAAN
취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.
The Vertiv Liebert GXT5 is a rack/tower uninterruptible power supply rated at 1000VA and 1000W with a 1.0 output power factor. It operates on 120V input through a NEMA 5-15P plug and accepts a wide 60-150V input range. The unit fits a 2U form factor and includes an RDU101 network management card for remote monitoring.
This UPS supports servers, network gear and medical equipment requiring pure sine-wave output with user-configurable voltage settings of 110, 115, 120 or 125VAC. It provides six NEMA 5-15R outlets, USB, serial and EPO ports plus environmental sensor support for temperature, humidity and leak detection. Sites without 120V utility service or NEMA 5-15 infrastructure cannot deploy this unit.
The unity power factor means the 1000VA rating equals 1000W of real power, so the full apparent capacity is available for modern power-factor-corrected loads. Energy Star 2.0 certification confirms efficient operation up to 104°F at elevations up to 9842.52 ft. Weighing 37 lbs in a 3.4 x 16.9 x 15.7 in chassis, it installs in standard racks or as a tower.
| Brand | Vertiv |
|---|---|
| Model | GXT5-1000LVRT2UXLTAAN |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000VA |
| Watts | 1000W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Dimensions | 3.4" x 16.9" x 15.7" |
| Weight | 37 lbs. |
| 배송 무게 | 22.63 kg |
| 포장 크기 | 617 × 569 × 262 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
This model is the 120V international version with a 60-150V input range and a NEMA 5-15P plug, so select it when your facility provides 120V utility power.
The 1.0 output power factor means the 1000VA rating equals 1000W of real power, so you can load the UPS up to 1000W without derating.
The RDU101 network card adds Ethernet-based monitoring and control, while the unit also offers USB, serial and EPO ports for local management.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?