Vertiv PSI5-1500RT120LI 1500VA 1350W 120V 2U UPS
- 120VAC Default; 100…
- 75-146 VAC
Vertiv
Line-interactive 3U rack/tower UPS delivers 3000VA with lithium-ion batteries lasting three times longer than lead-acid and recharging to 90% in two hours
Option PSI5-3000SRT120LI
취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.
The Vertiv PSI5-3000SRT120LI is a line-interactive UPS delivering 3000VA and 2700W in a 3U rack/tower chassis. It suits server rooms and network closets that need dense power protection with a short 16.9-inch depth for two-post or wall-mount racks. The unit provides ten outlets, including one NEMA L5-30R and nine NEMA 5-15/20R receptacles. Input connects via a NEMA L5-30P plug on a 120VAC default supply.
Lithium-ion cells operate from 32°F to 104°F and recharge to 90 percent in two hours. At full load the battery runs for 7.7 minutes; at half load it extends to 18.3 minutes. The design meets UL 1642, UL 1973, UL 1778 and CSA 22.2 No. 107.3 approvals. Surge protection follows ANSI C62.41 Category B. No fan noise or acoustic data is supplied in the specifications.
This model replaces older lead-acid UPS units of similar VA rating where longer battery life, faster recharge and reduced depth are required. The lithium-ion pack lasts up to three times longer than traditional batteries, lowering total cost of ownership over a five-year horizon. It is not suited for environments exceeding 40°C ambient or for loads beyond 2700W continuous. Remote monitoring requires an optional Intellislot network card.
| Brand | Liebert |
|---|---|
| Series | PSI5 |
| Model | PSI5-3000SRT120LI |
| International Version | 120VAC Default; 100/110/115/125VAC User Selectable |
| Input Voltage Range | 75-146 VAC |
| Input Frequency | 55~65Hz (57~63Hz Battery to Normal Comeback) |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 120 VAC Default; 100/110/115/125 VAC User Selectable |
| Outlets | 10 |
| Outlet Type | 1 x NEMA L5-30R, 9 x NEMA 5-15/20R |
| Battery Type | Lithium Ion |
| Battery Run Time | Full load: 7.7 min Half load: 18.3 min |
| Battery Recharge Time | 2hrs to 90% |
| Interface Port | USB |
| Approvals | UL 1642 (LiFe cells), UL 1973 (LiFe pack), UL 1778, CSA 22.2 no. 107.3 |
| Rackmountable | 3U Rack/Tower |
| Surge Protection | ANSI C62.41, Category B |
| Temperature | Operating Temperature,°F (°C): 32° to 104° (0° to 40°) Storage Temperature °F (°C): 5° to 120° (-15° to 50°) |
| Humidity | 20% - 90%, non-condensing |
| Dimensions | 5.14" x 17.24" x 16.92" |
| Weight | 56 lbs. |
| 배송 무게 | 30.84 kg |
| 포장 크기 | 620 × 580 × 295 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
Mount the 3U chassis using the included rail kit, then connect the NEMA L5-30P input to a 30 A branch circuit; the step often missed is selecting the correct output voltage (100/110/115/125 VAC) via the front-panel menu before powering on loads.
The LiFe cells are rated for up to three times the cycle life of VRLA packs; no user service is required, but plan on battery replacement after roughly 8–10 years or when runtime drops below the 7.7 min full-load / 18.3 min half-load figures.
At 2700 W the lithium-ion pack delivers 7.7 minutes of runtime; once that limit is reached the UPS shuts down, so the battery endurance is the first constraint under sustained full-load use.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?