저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

WMtec

WMtec 750W Platinum Common Slot Hot Plug Server Power Supply DPS-750AB-3

SKU CH-90DN-9EPMB

750 W Platinum hot-plug server PSU with common-slot design for ProLiant Gen8 systems

  • 750W output supports demanding server workloads
  • Platinum efficiency reduces energy costs and heat
  • Hot-plug design enables replacement without downtime
  • Common-slot form factor fits multiple ProLiant models
  • Wide 100-240V input works worldwide

750W Platinum Common-Slot PSU

This 750W Platinum-rated power supply uses the common-slot form factor and supports hot-plug replacement. It is designed for HPE ProLiant Gen8 servers including DL160, DL360E, DL360P, DL380E, DL380P, DL385P, ML350E V2, ML350P, SL2500, StoreVirtual 4530 and StoreEasy 1630. It accepts 100-240V AC input at 50-60Hz.

Replaces Gen8 common-slot units

It replaces earlier common-slot PSUs in the listed Gen8 platforms when a 750W Platinum unit is required. The jump is worth it when the existing supply has failed, when adding redundancy to a dual-slot chassis, or when consolidating to a single higher-efficiency unit. It is not for systems outside the Gen8 common-slot ecosystem or for builds needing a different wattage or form factor.

Hot-plug install in supported bays

Installation is a tool-less slide into a compatible common-slot bay while the server is running, provided the chassis supports hot-plug power. The unit locks with the integrated latch and begins sharing load immediately. Issues arise if the bay is not wired for redundant operation, if the server firmware does not recognise the part number, or if the latch is damaged during removal.

주요 특징

  • 750W output supports demanding server workloads
  • Platinum efficiency reduces energy costs and heat
  • Hot-plug design enables replacement without downtime
  • Common-slot form factor fits multiple ProLiant models
  • Wide 100-240V input works worldwide

사양

이 상품에 대해 아직 공개된 사양이 없습니다.

이 상품에 대한 질문

Will the DPS-750AB-3 slide into the common-slot bay of my ProLiant DL380P G8 without an adapter?

Yes, this 750W Platinum unit is a common-slot hot-plug PSU designed for the DL380P G8 and the other listed ProLiant G8 servers, so it fits the bay directly.

What is the correct hot-plug insertion sequence to avoid a power fault on the DPS-750AB-3?

Push the supply firmly into the bay until the latch clicks, letting the blind-mate connectors engage; the server will detect the 12.0V 62.5A main output and 12VSB 2.5A standby automatically.

How often should I clean the intake of the DPS-750AB-3 to maintain Platinum efficiency?

Inspect and vacuum the front intake every three to six months, or whenever dust builds up, to keep airflow over the internal components and sustain the 750W Platinum rating.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.