Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

MINUTEMAN

MINUTEMAN RPM2016N1LCD-20P Switched PDU 16-Outlet NEMA 5-20P 0U Vertical

SKU CH-4TRR-47MC5 MPN RPM2016N1LCD-20P

Switched PDU with 16 NEMA 5-15/20R outlets, 20 A input via NEMA 5-20P, 0U vertical mount, and IP-addressable remote outlet control

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)NEMA 5-20P
  • Cord Length10 ft
  • Switched PDU enables remote outlet control per device
  • Local LCD shows real-time amps and IP address
  • 0U vertical format fits 16 outlets in zero rack units
  • Network management via web browser, SNMP and SSH
  • Input circuit breaker protects all 16 connected loads

16-Outlet Switched PDU for Rack Deployment

The Minuteman RPM2016N1LCD-20P is a 0U vertical power distribution unit that delivers sixteen NEMA 5-15/20R receptacles from a single NEMA 5-20P input. It targets network administrators who need remote on/off control and real-time monitoring of connected servers, switches or security appliances. A local LCD reports current draw, IP address and environmental data at a glance.

Upgrade from Basic Unmonitored Strips

Replacing a non-networked power strip with this unit adds IP-addressable outlet switching, SNMP trap alerts and email notifications for overload or threshold events. The jump is worth it when uptime depends on rebooting frozen gear without a site visit or when you must track daily, weekly, monthly and yearly consumption across up to twenty-four devices from one IP address.

Verify Input Service and Mounting Space

Confirm the facility provides a 20 A circuit with a NEMA 5-20R receptacle to accept the 10 ft input cord. Ensure the rack offers a 0U vertical channel with enough clearance for the sixteen front-facing outlets and that your management network supports IPv4 or IPv6, SNMP v1/v2c/v3 and SSH for secure access.

Pluspunten

  • Switched PDU enables remote outlet control per device
  • Local LCD shows real-time amps and IP address
  • 0U vertical format fits 16 outlets in zero rack units
  • Network management via web browser, SNMP and SSH
  • Input circuit breaker protects all 16 connected loads

Specificaties

BrandMINUTEMAN
ModelRPM2016N1LCD-20P
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)NEMA 5-20P
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15/20R
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Verzendgewicht5.44 kg
Pakketafmetingen1359 × 221 × 109 mm

Andere versies van dit model

Nog 5 in dezelfde serie

Dezelfde familie, met ander geheugen, andere koeler of kloksnelheid — vergelijk voordat u beslist.

Vragen over dit artikel

Does the 0U vertical form factor with 16 NEMA 5-15/20R outlets require a specific rack depth or side-channel width to mount?

The 0U vertical style installs in the side channel of a standard rack using the included brackets; it does not consume horizontal rack units and fits typical 4-post cabinets.

What network configuration step is commonly missed when commissioning the built-in web server and SNMP on the RJ-45 port?

Connect the CAT5 cable to the 10/100 Base-T port, assign a static IPv4 or IPv6 address or enable DHCP, then configure SNMP v1, v2c or v3 community strings before managing outlets.

Which components of the RPM2016N1LCD-20P may need replacement after extended operation?

The internal input circuit breaker can be reset after an overload; the LCD panel and network module are not user-serviceable and would require factory service if they fail.