Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

Phanteks

Phanteks PH-F140M25R_G2_DWT01 140mm 25mm case fan

SKU CH-PT2B-2J3HP MPN PH-F140M25R_G2_DWT01

140 mm PWM fan with reversed blades, hydro bearing, 100.07 CFM max airflow, 2.04 mmH₂O pressure, 40.95 dBA max noise and daisy-chainable DRGB lighting via single Linq6 cable

  • Fan Counts1 Fan
  • Fan ControllerNo Controller
  • TypeCase Fan
  • Fan Size140mm
  • Fan Thickness25mm
  • Bearing TypeHydro Bearing

Fan Size 140mm

Style Reversed

Model M25 Gen2

  • M25 Gen2
  • M25
  • D30

Option Single Fan

Doorgestreepte varianten bestaan wel, maar zijn hier niet op voorraad.

  • Daisy-chain frame links multiple fans with one cable
  • Single Linq6 cable handles both PWM and D-RGB control
  • Hydro bearing runs 350-1800 RPM for 100.07 CFM airflow
  • 04 mmH₂O pressure suits radiators and dense heatsinks
  • White matte blades with infinity mirror D-RGB lighting

Single 140 mm case fan with reversed blades

The Phanteks M25-140 Gen2 Reversed is a 140 mm case fan built for radiators and heatsinks where pull airflow is required. It spins from 350 to 1800 RPM, moves up to 100.07 CFM and generates 2.04 mmH2O static pressure at a maximum of 40.95 dBA. The white matte blades and frame carry DRGB lighting with an infinity mirror effect.

Replaces single-cable fans lacking daisy-chain

Builders moving from individual PWM or 3-pin fans gain a Linq6 connector that merges power and lighting into one 500 mm cable, plus a unified frame that locks multiple units together. The jump is worth it when cable routing space is tight or when a radiator stack demands reversed blade direction for optimal intake or exhaust.

Limited to Phanteks NexLinq ecosystem for full

The single Linq6 cable requires a compatible NexLinq hub or controller to address DRGB effects and fan curves through the NexLinq App. Without that hardware the fan still runs on standard 4-pin PWM, but the infinity mirror lighting and daisy-chain linking cannot be configured. No other RGB protocol or motherboard header is supported.

Pluspunten

  • Daisy-chain frame links multiple fans with one cable
  • Single Linq6 cable handles both PWM and D-RGB control
  • Hydro bearing runs 350-1800 RPM for 100.07 CFM airflow
  • 04 mmH₂O pressure suits radiators and dense heatsinks
  • White matte blades with infinity mirror D-RGB lighting

Specificaties

BrandPhanteks
ModelM25-140 Gen2 Reversed
Part NumberPH-F140M25R_G2_DWT01
Fan Counts1 Fan
Fan ControllerNo Controller
TypeCase Fan
Fan Size140mm
Fan Thickness25mm
Bearing TypeHydro Bearing
RPM350-1800 +/- 10% RPM
Air Flow100.07 CFM Max
Air Pressure2.04 mmH2O
Noise Level40.95 dBA Max
Power ConnectorPWM, 2-Fase/4-poles
ColorWhite Matte Blade / White Fan Frame
LEDDRGB
Dimensions140 x 140 x 25 mm
Package ContentsM25-140 Gen2 Reversed Fan: 1x
Fan Screws: 5x
500mm Linq6 Extension Cable: 1x
Screw Cover Corner: 4x (2xL, 2xR)
Screw Cover Bridge: 2x
Installation Guide: 1x
Verzendgewicht0.27 kg
Pakketafmetingen152 × 150 × 51 mm

Andere versies van dit model

Nog 5 in dezelfde serie

Dezelfde familie, met ander geheugen, andere koeler of kloksnelheid — vergelijk voordat u beslist.

Vragen over dit artikel

What screw spacing does the 140mm fan use for case or radiator mounting?

The fan uses the standard 140mm square mounting pattern with 5 included screws that fit typical case fan holes and radiator threads.

How do I connect the Linq6 cable for both PWM control and DRGB lighting?

Plug the single 500mm Linq6 cable into a compatible Phanteks NexLinq hub or motherboard header that supports the combined signal; the daisy-chain frame then links additional fans without extra wires.

When should I clean or replace the hydro bearing fan?

Clean dust from the white blades and frame every few months with compressed air; the sealed hydro bearing is rated for long life and does not require lubrication, so replacement is only needed if noise or RPM drops noticeably.

Ook in deze afdeling

Klanten vergeleken ook

Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.