APC
APC SMX1500RM2UC Smart-UPS X 1500VA 2U 120V 8x 5-15R
Line-interactive UPS delivers 1350 W from eight NEMA 5-15R outlets in a 2U rackmount chassis with 645 J surge protection
- International Version120V
- Input Voltage Range75 - 154V Adjustable, 82 - 143V
- Input Frequency50/60 Hz +/- 3 Hz Auto-sensing
- Input ConnectionNEMA 5-15P
- VA Rating1440 VA
- Watts1350W
Options SMX1500RM2UC
- SMX750C
- SMX750CNC
- SMX1000CNC
- SMX1500RM2UC
- SMX1500RM2UCNC
Przekreślone wersje istnieją, ale nie są dostępne w tym miejscu.
- 1350W output protects critical servers during outages
- 8 NEMA 5-15R outlets connect rack equipment directly
- 8 minute half-load runtime extends safe shutdown window
- 645 joule surge rating shields hardware from spikes
- 2U rackmount form fits standard server cabinets
Smart-UPS X 1500VA rack/tower unit
The APC Smart-UPS X 1500VA is a line-interactive uninterruptible power supply designed for servers and network gear in a 2U rackmount or tower form factor. It accepts 120V input and provides eight NEMA 5-15R outlets for connected equipment. The unit includes a SmartConnect port for remote monitoring and an EPO port for emergency shutdown.
1350W output capacity
The UPS delivers 1440 VA and 1350 W of continuous power, which is the single figure that determines whether your load can be supported. Input voltage tolerance spans 75 to 154 V adjustable or 82 to 143 V default, with auto-sensing 50/60 Hz frequency. A NEMA 5-15P plug connects the unit to the utility supply.
Five minutes at full load
At 1350 W the internal lead-acid battery sustains output for 5 minutes, while half load extends runtime to 14.8 minutes. Recharge to full capacity takes 3 hours. Audible alarms signal on-battery, low-battery and overload conditions, and the unit carries CUL and UL 1778 approvals. Surge energy rating is 645 joules.
Najważniejsze cechy
- 1350W output protects critical servers during outages
- 8 NEMA 5-15R outlets connect rack equipment directly
- 8 minute half-load runtime extends safe shutdown window
- 645 joule surge rating shields hardware from spikes
- 2U rackmount form fits standard server cabinets
Specyfikacja
| Brand | APC |
|---|---|
| Series | Smart-UPS X |
| Model | SMX1500RM2UC |
| International Version | 120V |
| Input Voltage Range | 75 - 154V Adjustable, 82 - 143V |
| Input Frequency | 50/60 Hz +/- 3 Hz Auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1440 VA |
| Watts | 1350W |
| Output Voltage | 120V |
| Output Frequency | 50/60 Hz +/- 3 Hz Sync to mains |
| Outlets | 8 |
| Outlet Type | NEMA 5-15R |
| Battery Type | Lead Acid Battery |
| Battery Run Time | Full load: 5 min |
| Battery Recharge Time | 3 hour(s) |
| Battery Replaceable | CURK115-01-03 |
| Alarms | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
| Approvals | CUL listed, UL 1778 |
| Rackmountable | 2U |
| Surge Energy Rating | 645 Joules |
| Dimensions | 3.50" x 17.01" x 19.29" |
| Weight | 54.72 lbs. |
| Waga przesyłki | 30.91 kg |
| Wymiary opakowania | 635 × 597 × 241 mm |
Pytania dotyczące tego produktu
How long will the 1350W rating keep my servers running during a full-load outage?
At full 1350W load the internal lead-acid battery provides 5 minutes of runtime, giving enough time for graceful shutdown.
What does the NEMA 5-15P input connection limit in a 120V rack?
The 5-15P plug draws from a standard 120V 15A circuit, capping usable input to 1440 VA and 1350W continuous.
Will the 2U 17.01-inch depth fit my 19-inch rack cabinet?
Yes, the unit is 2U high, 17.01 inches deep and 19.29 inches wide, matching standard 19-inch EIA rack mounting.
Także w tym dziale
Klienci porównywali też te produkty
Ten sam dział, ta sama kasa — osiem kryptowalut i 30-minutowa blokada kursu.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear