Athena Power
Athena Power AP-RRU2MK1262 1200W 2U CRPS Redundant Server Power Supply
Redundant 2U CRPS server power supply delivering 1200W with 80 PLUS and 62368 safety certification
- TypeRedundant
- Single/RedundantRedundant
- Maximum Power1200W
- Main Connector24Pin
- Output Current+3.3V@12A, +5V@24A, [email protected] , +5Vsb@5A, [email pro
- Output+3.3V, +5V,+12V, +5Vsb, -12V
- 250,000-hour MTBF ensures long-term server reliability
- 94%+ efficiency reduces operating costs and heat
- IEC 62368 safety certification meets global compliance needs
- 2U CRPS modular design enables hot-swap redundancy
- 1200 W total output powers dense multi-GPU workloads
Redundant 2U server power supply
The Athena Power AP-RRU2MK1262 is a redundant 2U form factor switching power supply designed for servers, workstations and industrial automation equipment. It delivers a total capacity of 1200 Watts across two hot-swap modules. PMBus control allows the motherboard to monitor power status in real time. The unit meets 80 Plus Platinum efficiency and 62368 safety certification for worldwide compliance.
1200 W capacity with full-range input
Each module supplies up to 1200 W with output rails at +3.3V, +5V, +12V, +5Vsb and -12V. The supply operates on 90 to 264 Volts AC at 47 to 63 Hz, drawing 8 to 4 Amps depending on line voltage. Efficiency exceeds 94 percent under typical loads. Hold-up time is 11 ms minimum at nominal input, and protections include OCP and OVP. The design supports continuous full-load operation up to 55 °C.
Bundled cables cover ATX 3.1 and PCIe 5.0
Included connectors are a 24-pin ATX, two 8-pin EPS12V, eight 6+2-pin PCIe, six SATA and two floppy power plugs. A 12V-2x6 cable is supplied for ATX 3.1 compliance and PCIe 5.0 graphics support. This cable set lets the supply power modern multi-GPU servers without extra adapters. Builders needing different connector counts or form factors must source alternative units.
أبرز المميزات
- 250,000-hour MTBF ensures long-term server reliability
- 94%+ efficiency reduces operating costs and heat
- IEC 62368 safety certification meets global compliance needs
- 2U CRPS modular design enables hot-swap redundancy
- 1200 W total output powers dense multi-GPU workloads
المواصفات
| Brand | Athena Power |
|---|---|
| Model | AP-RRU2MK1262 |
| Type | Redundant |
| Single/Redundant | Redundant |
| Maximum Power | 1200W |
| Main Connector | 24Pin |
| Output Current | +3.3V@12A, +5V@24A, [email protected] , +5Vsb@5A, [email protected] |
| Output | +3.3V, +5V,+12V, +5Vsb, -12V |
| Input Voltage | 90 ~ 264 Volts AC |
| Input Frequency Range | 47 ~ 63 Hz |
| Input Current | 100~240V, 8 ~ 4A, 50~60Hz |
| MTBF | 250,000 Hours on Maximum Load at +25 degree C |
| Efficiency | >94% |
| Hold-up Time | 11 ms Minimum at Nominal Input Voltage |
| Protection | OCP, OVP, |
| Features | Rise time: Less than 70 ms |
| Dimensions | (L x W x H) 264 x 76 x 83.8 mm/ 10.4 x 3 x 3.3 in |
| Weight | 10.00 lbs |
| Humidity | 20%-90% |
| Temperature | Operating: 0°C ~ +55°C on Full Load; Storage & Shipping: -40°C ~ +70°C |
أسئلة حول هذا المنتج
Will the 1200W redundant unit fit and power my existing 2U server chassis that uses a 24-pin ATX and dual EPS 8-pin connectors?
Yes, the supply uses the CRPS 2U form factor (264 x 76 x 83.8 mm) and provides a 24-pin ATX connector plus two EPS 12V 8-pin connectors, matching standard 2U server backplanes.
How can I confirm the PMBus monitoring is active once the supply is installed?
The PMBus interface communicates with the motherboard; you can verify operation by reading voltage, current and temperature sensors through the server management software or BMC interface.