APC
APC AP8641 Metered-by-Outlet Switched PDU 200-240V 30A 21xC13 3xC19 0U Vertical
Metered-by-outlet switched PDU delivering 200-240V power with 21 C13 and 3 C19 outlets, 30A input, 0U vertical mounting
- TypeSwitched, Metered
- Rack Size0U
- StyleVertical
- CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL Listed, V
- ROHSYes
- Input Voltage200V, 208V, 230V
- Metered-by-outlet switching enables precise energy management per outlet
- 30 A input with NEMA L6-30P plug supports up to 5.0 kW load
- 21 C13 and 3 C19 outlets provide flexible rack power distribution
- 0U vertical mounting saves valuable rack space for equipment
- 8 ft cord length allows versatile placement in the rack row
Metered-by-outlet switched PDU for rack power
The APC AP8641 distributes 200–240 V input through a NEMA L6-30P plug at up to 30 A, delivering power to twenty-one C13 and three C19 outlets. Real-time metering and on/off switching at each outlet give administrators granular energy visibility and remote reboot capability in a 0U vertical form factor.
Thermal range and power envelope
The unit operates from -5 °C to 45 °C at up to 95 % relative humidity and elevations to 3000 m. Regulatory derating limits continuous input to 24 A, while the 9.84 ft cord connects to a 5.0 kW rated supply without requiring active cooling or producing audible fan noise.
cUL and UL listed with multiple agency marks
Certifications include cUL Listed, UL Listed, FCC Part 15 Class A, ICES-003, PSE and VCCI Class A, plus RoHS compliance. These marks confirm suitability for commercial data-centre deployments in North America and Japan, while the vertical mounting style preserves rack space for compute equipment.
Points forts
- Metered-by-outlet switching enables precise energy management per outlet
- 30 A input with NEMA L6-30P plug supports up to 5.0 kW load
- 21 C13 and 3 C19 outlets provide flexible rack power distribution
- 0U vertical mounting saves valuable rack space for equipment
- 8 ft cord length allows versatile placement in the rack row
Caractéristiques
| Brand | APC |
|---|---|
| Series | Metered By Outlet With Switching |
| Model | AP8641 |
| Type | Switched, Metered |
| Rack Size | 0U |
| Style | Vertical |
| Certifications | cUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VCCI Class A |
| ROHS | Yes |
| Input Voltage | 200V, 208V, 230V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 30A |
| Regulatory Derated Input Current | 24A |
| Input Connector(s) | NEMA L6-30P |
| Cord Length | 9.84 Feet |
| Output Voltage | 200V, 208V |
| Output Connector(s) | 3 x IEC 320 C19 (Battery Backup) 21 x IEC 320 C13 (Battery Backup) |
| Operating Environment | -5 - 45 ºC |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 ºC |
| Storage Relative Humidity | 5 - 95% |
| Storage Elevation | 0 - 15000 m |
| Features | Alarm Thresholds Network Management Capabilities Power Delays Local Current Monitoring Display Remote Individual Outlet Control Metering-by-Outlet capability Flash Upgradeable Load indicator LED Integrates with StruxureWare Data Center Expert |
| Dimensions | 7.20" x 2.20" x 2.00" |
| Weight | 18.10 lbs. |
| Poids d’expédition | 10.89 kg |
| Dimensions du colis | 2057 × 178 × 127 mm |
Questions sur cet article
How is the 0U vertical PDU mounted and what step is often missed?
Mount the unit vertically in a 0U rack channel using the included brackets; the step often missed is securing the cord-retention clips so the 9.84 ft NEMA L6-30P cable cannot pull loose.
What maintenance will the AP8641 need over time?
Periodically vacuum dust from the vent slots and verify the outlet-metering firmware is current; no user-replaceable parts such as batteries or filters are present.
At what sustained load does the 24 A derated limit activate?
The regulatory derated input current is 24 A; continuous draw above that level will trip the internal branch-circuit protection first.