Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

APC

APC AP8641 Metered-by-Outlet Switched PDU 200-240V 30A 21xC13 3xC19 0U Vertical

SKU CH-ZGH0-WTZZY MPN AP8641

Metered-by-outlet switched PDU delivering 200-240V power with 21 C13 and 3 C19 outlets, 30A input, 0U vertical mounting

  • TypeSwitched, Metered
  • Rack Size0U
  • StyleVertical
  • CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL Listed, V
  • ROHSYes
  • Input Voltage200V, 208V, 230V
  • Metered-by-outlet switching enables precise energy management per outlet
  • 30 A input with NEMA L6-30P plug supports up to 5.0 kW load
  • 21 C13 and 3 C19 outlets provide flexible rack power distribution
  • 0U vertical mounting saves valuable rack space for equipment
  • 8 ft cord length allows versatile placement in the rack row

Metered-by-outlet switched PDU for rack power

The APC AP8641 distributes 200–240 V input through a NEMA L6-30P plug at up to 30 A, delivering power to twenty-one C13 and three C19 outlets. Real-time metering and on/off switching at each outlet give administrators granular energy visibility and remote reboot capability in a 0U vertical form factor.

Thermal range and power envelope

The unit operates from -5 °C to 45 °C at up to 95 % relative humidity and elevations to 3000 m. Regulatory derating limits continuous input to 24 A, while the 9.84 ft cord connects to a 5.0 kW rated supply without requiring active cooling or producing audible fan noise.

cUL and UL listed with multiple agency marks

Certifications include cUL Listed, UL Listed, FCC Part 15 Class A, ICES-003, PSE and VCCI Class A, plus RoHS compliance. These marks confirm suitability for commercial data-centre deployments in North America and Japan, while the vertical mounting style preserves rack space for compute equipment.

Pluspunten

  • Metered-by-outlet switching enables precise energy management per outlet
  • 30 A input with NEMA L6-30P plug supports up to 5.0 kW load
  • 21 C13 and 3 C19 outlets provide flexible rack power distribution
  • 0U vertical mounting saves valuable rack space for equipment
  • 8 ft cord length allows versatile placement in the rack row

Specificaties

BrandAPC
SeriesMetered By Outlet With Switching
ModelAP8641
TypeSwitched, Metered
Rack Size0U
StyleVertical
CertificationscUL Listed, FCC Part 15 Class A, ICES-003, PSE, UL Listed, VCCI Class A
ROHSYes
Input Voltage200V, 208V, 230V
Input Frequency50/60 Hz
Maximum Input Current30A
Regulatory Derated Input Current24A
Input Connector(s)NEMA L6-30P
Cord Length9.84 Feet
Output Voltage200V, 208V
Output Connector(s)3 x IEC 320 C19 (Battery Backup)
21 x IEC 320 C13 (Battery Backup)
Operating Environment-5 - 45 ºC
Operating Relative Humidity5 - 95%
Operating Elevation0 - 3000 m
Storage Temperature-25 - 65 ºC
Storage Relative Humidity5 - 95%
Storage Elevation0 - 15000 m
FeaturesAlarm Thresholds
Network Management Capabilities
Power Delays
Local Current Monitoring Display
Remote Individual Outlet Control
Metering-by-Outlet capability
Flash Upgradeable
Load indicator LED
Integrates with StruxureWare Data Center Expert
Dimensions7.20" x 2.20" x 2.00"
Weight18.10 lbs.
Verzendgewicht10.89 kg
Pakketafmetingen2057 × 178 × 127 mm

Vragen over dit artikel

How is the 0U vertical PDU mounted and what step is often missed?

Mount the unit vertically in a 0U rack channel using the included brackets; the step often missed is securing the cord-retention clips so the 9.84 ft NEMA L6-30P cable cannot pull loose.

What maintenance will the AP8641 need over time?

Periodically vacuum dust from the vent slots and verify the outlet-metering firmware is current; no user-replaceable parts such as batteries or filters are present.

At what sustained load does the 24 A derated limit activate?

The regulatory derated input current is 24 A; continuous draw above that level will trip the internal branch-circuit protection first.