APC
APC SMX3000RMHV2UNC Smart-UPS X 3000VA 2700W 2U Rack/Tower UPS with Network Card
Rack/tower UPS delivers 2700 W from 3000 VA with 11 IEC outlets and network management card
- International Version208V, 230V
- Input Voltage Range140 - 280V
- Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
- Input ConnectionBritish BS1363A IEC-320 C20 Schuko CEE 7/EU1-16P
- VA Rating3000 VA
- Watts2700 Watts
Options SMX3000RMHV2UNC
- SMX3000RMHV2UNC
- SMX1500RM2UNC
- SMX2000LV
- SMX2000LVNC
- SMX2000RMLV2U
- SMX2000RMLV2UNC
- SMX2200HV
- SMX2200RMHV2U
- SMX2200RMLV2U
- SMX2200R2HVNC
- SMX2200HVNC
- SMX3000HV
他に 7点の構成を表示
- SMX3000LV
- SMX3000LVNC
- SMX3000RMHV2U
- SMX3000RMLV2U
- SMX3000RMLV2UNC
- SMX3000HVNC
- SMX3000HVT
取り消し線の付いたバージョンは存在しますが、こちらでは取り扱っていません。
- 2700 W output protects servers and network gear
- 11 IEC outlets (8 C13, 1 C19, 2 jumpers) power dense racks
- 2U rack/tower form factor fits standard cabinets
- SmartSlot network card enables remote monitoring
- 3-hour recharge keeps backup ready fast
3000 VA rack/tower UPS with network card
The APC Smart-UPS X delivers 2700 watts of battery-backed power for servers, network gear and point-of-sale equipment. It accepts 208 V or 230 V input and provides 230 V output through eleven IEC outlets. A pre-installed network management card enables remote monitoring and control over IP.
Automatic voltage regulation
AVR corrects low and high voltage conditions between 140 V and 280 V without using battery capacity, preserving runtime for genuine outages. Temperature-compensated charging adjusts voltage to battery temperature, extending service life. Recharge to full capacity takes three hours after a discharge event.
SmartSlot interface and replaceable battery
The SmartSlot bay accepts optional management accessories for environmental sensors or additional connectivity. Battery replacement uses the APCRBC117 or APCRBC117J cartridge, which can be swapped without powering down connected loads. Configurable low-battery alarms and a 645 joule surge rating complete the protection set.
特長
- 2700 W output protects servers and network gear
- 11 IEC outlets (8 C13, 1 C19, 2 jumpers) power dense racks
- 2U rack/tower form factor fits standard cabinets
- SmartSlot network card enables remote monitoring
- 3-hour recharge keeps backup ready fast
仕様
| Brand | APC |
|---|---|
| Series | Smart-UPS X |
| Model | SMX3000RMHV2UNC |
| International Version | 208V, 230V |
| Input Voltage Range | 140 - 280V |
| Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
| Input Connection | British BS1363A IEC-320 C20 Schuko CEE 7/EU1-16P |
| VA Rating | 3000 VA |
| Watts | 2700 Watts |
| Output Voltage | 230V |
| Output Frequency | 50/60Hz +/- 3 Hz |
| Outlets | 11 |
| Outlet Type | (8) IEC 320 C13 (1) IEC 320 C19 (2) IEC Jumpers |
| Battery Recharge Time | 3 hour(s) |
| Battery Replaceable | APCRBC117, APCRBC117J |
| Alarms | Alarm when on battery: distinctive low battery alarm: configurable delays |
| Interface Port | Smart-Slot |
| Rackmountable | 2U |
| Surge Energy Rating | 645 Joules |
| Dimensions | 3.35" x 17.01" x 26.26" |
| Weight | 82.28 lbs. |
| 配送重量 | 45.26 kg |
| 梱包サイズ | 869 × 596 × 243 mm |
このモデルの他のバージョン
同シリーズにさらに 5点
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
APC SMX2000RMLV2UNC 2000 VA UPS 1800 W 120V 2U Rack/Tower
- 120V
- 70 - 153V Adjustabl…
APC SMX2200RMHV2U Smart-UPS X 2200 VA 1980 W 2U Rack/Tower UPS
- 208V, 230V
- 140 - 280V
APC SMX3000LVNC UPS 2880 VA 2700 W 120 V 10 Outlets 4U
- 120V
- 50/60 Hz +/- 3 Hz (…
APC SMX3000RMLV2UNC 3000 VA 2700 W UPS 120V 2U Rackmount/Tower
- 120V
- 70 - 153V
この商品に関する質問
How do I install the APCRBC117 or APCRBC117J battery modules, and which step is commonly missed?
Slide the modules into the front battery compartment and firmly press the connector until it clicks; the step often missed is securing the retaining bracket screws that lock the modules in place.
What replacement battery cartridges will this UPS need, and are they hot-swappable?
It uses APCRBC117 or APCRBC117J cartridges; they are hot-swappable so you can replace them without powering down connected equipment.
What is the first limit reached during a long runtime event on battery?
The 2700 W / 3000 VA output capacity is the first limit; once the connected load exceeds that rating the UPS will shut down to protect itself.
同じ売り場の商品
よく比較されている商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case