APC
APC SMX2000LVNC Smart-UPS 1920VA 1800W 120V UPS
Pure sine-wave battery backup delivers 1920 VA and 1800 W through ten NEMA outlets with a pre-installed network management card and extended-run capability
- International Version120V
- Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
- Input ConnectionNEMA 5-20P
- VA Rating1920 VA
- Watts1800 Watts
- Output Voltage120V
Options SMX2000LVNC
- SMX2000LVNC
- SMX1500RM2UNC
- SMX2000LV
- SMX2000RMLV2U
- SMX2000RMLV2UNC
- SMX2200HV
- SMX2200RMHV2U
- SMX2200RMLV2U
- SMX2200R2HVNC
- SMX2200HVNC
- SMX3000HV
- SMX3000LV
他に 7点の構成を表示
- SMX3000LVNC
- SMX3000RMHV2U
- SMX3000RMLV2U
- SMX3000RMLV2UNC
- SMX3000RMHV2UNC
- SMX3000HVNC
- SMX3000HVT
取り消し線の付いたバージョンは存在しますが、こちらでは取り扱っていません。
- 1920 VA / 1800 W pure sine wave output protects sensitive servers
- Pre-installed AP9631 network card enables remote monitoring and environmental alerts
- Extended-run design accepts SMX120BP battery packs for longer outage runtime
- Ten mixed NEMA outlets (L5-20R, 5-20R, 5-15R) power diverse rack equipment
- Tower or 4U rackmount form factor fits data-centre or office deployment
Purpose-Built Power Protection
The APC SMX2000LVNC is a 1920VA 1800W line-interactive UPS that delivers pure sine-wave output at 120V. It ships with a pre-installed Network Management Card for remote monitoring and environmental alerts. The unit fits a tower footprint or a 4U rack space with optional rails.
Ideal For Dense Rack Deployments
This model suits server rooms and network closets that need extended runtime capability through external battery packs and a compact 17-inch depth. It is not suited for sites that require 100-127V output outside the 120V nominal setting or for installations that cannot accommodate a NEMA 5-20P input connection.
Deciding Specification
The single figure that determines fit is the 1920VA 1800W rating combined with the NEMA 5-20P input plug; if your circuit and load calculations fall within this capacity the unit will support the attached equipment.
特長
- 1920 VA / 1800 W pure sine wave output protects sensitive servers
- Pre-installed AP9631 network card enables remote monitoring and environmental alerts
- Extended-run design accepts SMX120BP battery packs for longer outage runtime
- Ten mixed NEMA outlets (L5-20R, 5-20R, 5-15R) power diverse rack equipment
- Tower or 4U rackmount form factor fits data-centre or office deployment
仕様
| Brand | APC |
|---|---|
| Series | Smart-UPS |
| Model | SMX2000LVNC |
| International Version | 120V |
| Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
| Input Connection | NEMA 5-20P |
| VA Rating | 1920 VA |
| Watts | 1800 Watts |
| Output Voltage | 120V |
| Output Frequency | 50/60 Hz +/- 3 Hz |
| Outlets | 10 |
| Outlet Type | 1 x NEMA L5-20R 3 x NEMA 5-20R 6 x NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Recharge Time | 3 hour(s) |
| Battery Replaceable | APCRBC143 |
| Alarms | Alarm when on battery : distinctive low battery alarm : configurable delays |
| Interface Port | RJ-45 Serial, USB |
| Management Software | YES |
| Approvals | BSMI, CSA, EN 50091-2, EN 55022 Class A, ENERGY STAR (USA), FCC Part 15 Class A, NOM, TUV, UL 1778, VCCI Class A |
| Rackmountable | 4U |
| Surge Energy Rating | 540 Joules |
| Features | APC Smart-UPS, 1800 Watts /1920 VA, Input 120V / Output 120V, Interface Port RJ-45 Serial, USB, Extended runtime model, Rack Height 4 U |
| Dimensions | 7.00" x 19.00" x 17.00" |
| Weight | 85.00 lbs. |
| Package Contents | APC Smart-UPS X 2000VA Rack/Tower LCD 100-127V with Network Card, CD with software, Documentation CD, Installation guide, Network Management Card, Rack Mounting brackets, Rack mounting hardware, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable |
| 配送重量 | 47.63 kg |
| 梱包サイズ | 633 × 586 × 330 mm |
このモデルの他のバージョン
同シリーズにさらに 5点
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
APC SMX3000LV UPS 3000 VA 2700 W 120 V 10 Outlets 4U
- 120V
- 70 V AC to 153 V AC…
APC SMX2200RMLV2U Smart-UPS X 2200VA 1980W 2U Rack/Tower 120V 8 Outlets SmartSlot
- 120V
- 70 - 153V
APC SMX3000RMLV2U UPS 3000 VA 2700 W 120 V 2U Rack/Tower
- 120V
- 50/60 Hz +/- 3 Hz (…
この商品に関する質問
Which battery cartridge replaces the sealed lead-acid cells in the SMX2000LVNC?
The replaceable cartridge is the APCRBC143 sealed lead-acid pack, which the unit recharges in about three hours after a full discharge.
At what load does the 1800-watt output ceiling become the first constraint during continuous operation?
The 1800-watt rating is the hard limit; any connected equipment drawing more than that will overload the inverter even if the 1920 VA apparent-power headroom remains.
How much heat does the UPS add to a rack when it runs all day at full load?
At full load the unit dissipates the difference between input and output power as heat; the 540-joule surge rating and ENERGY STAR certification indicate efficient operation, but exact thermal output varies with load and ambient temperature.