暗号資産でのお支払いに対応—お手持ちのコインで、本物のハードウェアをご購入いただけます。暗号資産で支払い、本物のハードウェアに使う。 $399以上のご注文で、世界中どこでも送料無料(保険付き)。無地・ノーブランドの外箱で、ドイツから発送いたします。$399以上で送料無料(保険付き)。 注文手続きを開始すると、レートは30分間ロックされます。レートは30分間ロック。 すべての商品は未開封で、シリアル番号を確認した上で、24か月保証が付いています。未開封、24か月保証。

ウォッチリスト ログイン

HP

HP X312 1000W 54VDC Power Supply 0957-2312 (J9580A)

SKU CH-B9NB-6BD5T

Delivers 1000 W of 54 V DC power to compatible HP E3800 switches and Data Vault X312 servers from a 100-240 V AC source

  • TypeProprietary Power Supply
  • Delivers stable 54 V DC output for reliable server operation
  • Accepts worldwide 100-240 V AC input without manual switching
  • Provides 1000 W capacity to power demanding HP equipment
  • Designed for HP E3800 Switch Series and Data Vault X312
  • Genuine HP part J9580A ensures exact fit and compatibility

HP X312 1000W 54VDC power supply

This proprietary 1000 watt unit converts 100 to 240 volt AC mains input into a regulated 54 volt DC output. It is built for the HP E3800 switch series and Data Vault X312 server where a direct-replacement internal module is required.

Thermals noise and power draw

The supply accepts both 110 volt and 220 volt AC sources across the full 100 to 240 volt range, delivering up to 1 kilowatt at the 54 volt rail. Internal cooling and acoustic profile are managed by the host chassis, so thermal and noise behaviour follows the switch or server design rather than the module alone.

Bundled accessories and software

No extra cables, mounting brackets or configuration utilities are included with the module. Installation relies on the existing chassis slot and backplane connectors of the compatible E3800 or X312 hardware, so nothing additional needs to be sourced or configured.

特長

  • Delivers stable 54 V DC output for reliable server operation
  • Accepts worldwide 100-240 V AC input without manual switching
  • Provides 1000 W capacity to power demanding HP equipment
  • Designed for HP E3800 Switch Series and Data Vault X312
  • Genuine HP part J9580A ensures exact fit and compatibility

仕様

TypeProprietary Power Supply

この商品に関する質問

How is the HP X312 1000W power supply installed in the Data Vault X312 server, and what step is often missed?

Slide the unit into the internal bay until the latch clicks, then secure the retention screw; the step often missed is tightening that screw, which prevents the supply from unseating under vibration.

What maintenance or replacement will the HP J9580A power supply need over its service life?

The internal fan bearings are the primary wear item; plan to replace the entire supply when airflow drops or bearing noise appears, as the proprietary form factor does not allow fan-only servicing.

What is the first limit reached when the HP 0957-2312 runs at full 1000W output continuously?

Thermal protection engages first; sustained 1 kW load at 54 V DC raises internal temperatures until the over-temperature circuit shuts the unit down to prevent damage.

同じ売り場の商品

よく比較されている商品

同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。