我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

HP

HP X312 1000W 54VDC Power Supply 0957-2312 (J9580A)

SKU CH-B9NB-6BD5T

Delivers 1000 W of 54 V DC power to compatible HP E3800 switches and Data Vault X312 servers from a 100-240 V AC source

  • TypeProprietary Power Supply
  • Delivers stable 54 V DC output for reliable server operation
  • Accepts worldwide 100-240 V AC input without manual switching
  • Provides 1000 W capacity to power demanding HP equipment
  • Designed for HP E3800 Switch Series and Data Vault X312
  • Genuine HP part J9580A ensures exact fit and compatibility

HP X312 1000W 54VDC power supply

This proprietary 1000 watt unit converts 100 to 240 volt AC mains input into a regulated 54 volt DC output. It is built for the HP E3800 switch series and Data Vault X312 server where a direct-replacement internal module is required.

Thermals noise and power draw

The supply accepts both 110 volt and 220 volt AC sources across the full 100 to 240 volt range, delivering up to 1 kilowatt at the 54 volt rail. Internal cooling and acoustic profile are managed by the host chassis, so thermal and noise behaviour follows the switch or server design rather than the module alone.

Bundled accessories and software

No extra cables, mounting brackets or configuration utilities are included with the module. Installation relies on the existing chassis slot and backplane connectors of the compatible E3800 or X312 hardware, so nothing additional needs to be sourced or configured.

商品特色

  • Delivers stable 54 V DC output for reliable server operation
  • Accepts worldwide 100-240 V AC input without manual switching
  • Provides 1000 W capacity to power demanding HP equipment
  • Designed for HP E3800 Switch Series and Data Vault X312
  • Genuine HP part J9580A ensures exact fit and compatibility

商品規格

TypeProprietary Power Supply

商品問答

How is the HP X312 1000W power supply installed in the Data Vault X312 server, and what step is often missed?

Slide the unit into the internal bay until the latch clicks, then secure the retention screw; the step often missed is tightening that screw, which prevents the supply from unseating under vibration.

What maintenance or replacement will the HP J9580A power supply need over its service life?

The internal fan bearings are the primary wear item; plan to replace the entire supply when airflow drops or bearing noise appears, as the proprietary form factor does not allow fan-only servicing.

What is the first limit reached when the HP 0957-2312 runs at full 1000W output continuously?

Thermal protection engages first; sustained 1 kW load at 54 V DC raises internal temperatures until the over-temperature circuit shuts the unit down to prevent damage.