暗号資産でのお支払いに対応—お手持ちのコインで、本物のハードウェアをご購入いただけます。暗号資産で支払い、本物のハードウェアに使う。 $399以上のご注文で、世界中どこでも送料無料(保険付き)。無地・ノーブランドの外箱で、ドイツから発送いたします。$399以上で送料無料(保険付き)。 注文手続きを開始すると、レートは30分間ロックされます。レートは30分間ロック。 すべての商品は未開封で、シリアル番号を確認した上で、24か月保証が付いています。未開封、24か月保証。

ウォッチリスト ログイン

ICY DOCK

ICY DOCK flexiDOCK MB014SP-B R1 4 Bay 2.5" SATA/SAS Hot-Swap Docking Enclosure for 5.25" Bay

SKU CH-SRRZ-DS7N9

Hot-swap four 2.5″ SATA/SAS drives in a 5.25″ bay with tray-less ejection and a 40 mm fan

  • Holds four 2.5" SATA or SAS drives in one 5.25" bay
  • Tray-less design allows tool-free hot-swap of bare drives
  • Individual power buttons and improved ejection mechanism per bay
  • Adjustable 40 mm fan with on/off jumper for thermal control
  • Locking SATA cables and full metal chassis ensure secure connections

4-Bay 2.5" SATA/SAS Hot-Swap Dock

This enclosure fits a standard 5.25" optical drive bay and holds four 2.5" SATA or SAS drives between 5 mm and 9.5 mm thick. A self-adjusting stabilizer secures 7 mm drives, while the tray-less, door-less design lets you insert or remove bare drives without tools. It targets professionals who swap multiple drives frequently and need quick, direct access.

Check 5.25" bay availability and host interface

Verify that your chassis has a free external 5.25" bay and that your motherboard or controller provides enough SATA 3.0 6Gbps or SAS 3.0 12Gbps ports for the number of drives you plan to use. A SAS host is required for SAS drives; SATA drives work on either interface. Ensure you have matching data and power cables with locking latches for secure connections.

Sustained thermal management under load

A 40 mm fan with adjustable speed control and an on/off jumper actively cools all four bays during extended operation. The full metal chassis and industrial ABS plastic dissipate heat while protecting drives during continuous read/write cycles. Individual power buttons let you spin down unused drives, reducing overall thermal load without removing them.

特長

  • Holds four 2.5" SATA or SAS drives in one 5.25" bay
  • Tray-less design allows tool-free hot-swap of bare drives
  • Individual power buttons and improved ejection mechanism per bay
  • Adjustable 40 mm fan with on/off jumper for thermal control
  • Locking SATA cables and full metal chassis ensure secure connections

仕様

この商品の仕様はまだ公開されていません。

この商品に関する質問

Does the flexiDOCK MB014SP-B R1 include the four 2.5" SATA/SAS drives or must they be purchased separately?

The enclosure holds four 2.5" SATA or SAS SSDs or HDDs from 5 mm to 9.5 mm thick; drives are not included and must be supplied by the user.

Should I choose the SATA 3.0 6 Gbps or the SAS 3.0 12 Gbps interface for my system?

Use SATA 3.0 6 Gbps with a standard SATA controller; choose SAS 3.0 12 Gbps only if your host has a single-channel SAS controller that can address all four bays.

What does the 12 Gbps SAS figure mean once the unit is installed in a 5.25" bay?

Each bay can transfer at up to 12 Gbps when driven by a compatible SAS host, but the actual throughput will match the slowest link in your controller, cables and drives.

同じ売り場の商品

よく比較されている商品

同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。