暗号資産でのお支払いに対応—お手持ちのコインで、本物のハードウェアをご購入いただけます。暗号資産で支払い、本物のハードウェアに使う。 $399以上のご注文で、世界中どこでも送料無料(保険付き)。無地・ノーブランドの外箱で、ドイツから発送いたします。$399以上で送料無料(保険付き)。 注文手続きを開始すると、レートは30分間ロックされます。レートは30分間ロック。 すべての商品は未開封で、シリアル番号を確認した上で、24か月保証が付いています。未開封、24か月保証。

ウォッチリスト ログイン

LORDWORLD

LORDWORLD Analog Turbidity Sensor 0-4000NTU

SKU CH-Q9KN-5VVF6

Measures water turbidity from 0-4000NTU with analog or digital output in under 500ms for Arduino, ESP32, STM32 or Raspberry Pi

  • Compatible with Arduino, ESP32, STM32, Raspberry Pi (ADC required)
  • Dual analog 0-4.5V and digital high/low output for flexible integration
  • Measures 0-4000 NTU turbidity with
  • Comprehensive tutorials available on DFRobot website
  • Submerge only the small round probe head; top is not waterproof

Target Platforms

The LORDWORLD turbidity sensor is an analog development board that connects to Arduino, ESP32, STM32 or Raspberry Pi boards through an ADC input. It measures water cloudiness from 0 to 4000 NTU and delivers a reading in under 500 ms.

Use-Case Fit

Makers building portable water-quality loggers, environmental monitoring stations or lab test rigs will find the dual analog and digital outputs convenient. Projects that require a fully submersible probe or a waterproof connector should look elsewhere because the probe head is not sealed.

Deciding Specification

The single figure that determines suitability is the 0-4000 NTU measurement range combined with a sub-500 ms response time. If your application needs a wider turbidity span or faster sampling, this board will not meet the requirement.

特長

  • Compatible with Arduino, ESP32, STM32, Raspberry Pi (ADC required)
  • Dual analog 0-4.5V and digital high/low output for flexible integration
  • Measures 0-4000 NTU turbidity with
  • Comprehensive tutorials available on DFRobot website
  • Submerge only the small round probe head; top is not waterproof

仕様

BrandLORDWORLD

この商品に関する質問

How do I wire the analog output to an Arduino or Raspberry Pi ADC, and what wiring mistake causes wrong readings?

Connect the signal pin to an analog input, VCC to the supply voltage, and GND to ground; the common error is leaving the ADC reference unmatched to the supply so the 0-4.5 V span reads incorrectly.

What part will need cleaning or replacement after long-term use in wastewater or river water?

The small round sensing head fouls with sediment and bio-film; wipe it gently or replace the probe module when calibration no longer restores accurate 0-4000 NTU readings.

At what turbidity level does the sensor saturate and stop distinguishing higher values during continuous monitoring?

The output reaches full scale at 4000 NTU, so any water cloudier than that reads the same maximum voltage and cannot be resolved further.

同じ売り場の商品

よく比較されている商品

同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。