저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

LORDWORLD

LORDWORLD Analog Turbidity Sensor 0-4000NTU

SKU CH-Q9KN-5VVF6

Measures water turbidity from 0-4000NTU with analog or digital output in under 500ms for Arduino, ESP32, STM32 or Raspberry Pi

  • Compatible with Arduino, ESP32, STM32, Raspberry Pi (ADC required)
  • Dual analog 0-4.5V and digital high/low output for flexible integration
  • Measures 0-4000 NTU turbidity with
  • Comprehensive tutorials available on DFRobot website
  • Submerge only the small round probe head; top is not waterproof

Target Platforms

The LORDWORLD turbidity sensor is an analog development board that connects to Arduino, ESP32, STM32 or Raspberry Pi boards through an ADC input. It measures water cloudiness from 0 to 4000 NTU and delivers a reading in under 500 ms.

Use-Case Fit

Makers building portable water-quality loggers, environmental monitoring stations or lab test rigs will find the dual analog and digital outputs convenient. Projects that require a fully submersible probe or a waterproof connector should look elsewhere because the probe head is not sealed.

Deciding Specification

The single figure that determines suitability is the 0-4000 NTU measurement range combined with a sub-500 ms response time. If your application needs a wider turbidity span or faster sampling, this board will not meet the requirement.

주요 특징

  • Compatible with Arduino, ESP32, STM32, Raspberry Pi (ADC required)
  • Dual analog 0-4.5V and digital high/low output for flexible integration
  • Measures 0-4000 NTU turbidity with
  • Comprehensive tutorials available on DFRobot website
  • Submerge only the small round probe head; top is not waterproof

사양

BrandLORDWORLD

이 상품에 대한 질문

How do I wire the analog output to an Arduino or Raspberry Pi ADC, and what wiring mistake causes wrong readings?

Connect the signal pin to an analog input, VCC to the supply voltage, and GND to ground; the common error is leaving the ADC reference unmatched to the supply so the 0-4.5 V span reads incorrectly.

What part will need cleaning or replacement after long-term use in wastewater or river water?

The small round sensing head fouls with sediment and bio-film; wipe it gently or replace the probe module when calibration no longer restores accurate 0-4000 NTU readings.

At what turbidity level does the sensor saturate and stop distinguishing higher values during continuous monitoring?

The output reaches full scale at 4000 NTU, so any water cloudier than that reads the same maximum voltage and cannot be resolved further.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.