저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

APC

APC BK500BLK UPS 500 VA 300 W 120 V 6 Outlets

SKU CH-C9ZF-X3202 MPN BK500BLK

Provides 300 W battery backup and 480 J surge protection across six outlets with USB and phone-line interfaces

  • International Version120V
  • Input Voltage Range98 - 140V
  • Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
  • Input ConnectionNEMA 5-15P
  • VA Rating500 VA
  • Watts300 Watts

VA 500 VA

  • 350 VA
  • 500 VA

취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.

  • Battery backup keeps systems running for 15 minutes at half load
  • 300 watts of continuous power supports desktop PC and monitor
  • 480 joules surge protection shields equipment from voltage spikes
  • USB and RS-232 ports enable automatic shutdown via management software
  • Data-line protection guards modem, fax or DSL connection through RJ-11 port

Compact standby UPS

The APC BK500BLK is a 500 VA standby battery backup with six NEMA 5-15R outlets. Three outlets provide battery-backed power and surge protection, while the remaining three deliver surge protection only. It accepts 98 to 140 V input and supplies 120 V output through a NEMA 5-15P plug. A sealed lead-acid battery recharges in eight hours and is user-replaceable with RBC2 or RBC2J packs.

Desktop and networking protection

This unit suits home-office PCs, routers, modems and phone-line equipment needing brief ride-through during outages. Data-line protection covers analog phone, fax, modem or DSL connections via an RJ-11 port. USB and DB-9 RS-232 interfaces enable monitoring and graceful shutdown software. Equipment requiring continuous pure sine-wave output or longer runtime at full load should look at other topologies.

300 watt output limit

The UPS delivers a maximum of 300 watts on its battery-backed outlets. Add the power draw of every device you plan to connect to those three outlets; if the total exceeds 300 W the unit will overload and alarm. The half-load runtime is 15 minutes and full-load runtime is 3 minutes, so plan loads accordingly.

주요 특징

  • Battery backup keeps systems running for 15 minutes at half load
  • 300 watts of continuous power supports desktop PC and monitor
  • 480 joules surge protection shields equipment from voltage spikes
  • USB and RS-232 ports enable automatic shutdown via management software
  • Data-line protection guards modem, fax or DSL connection through RJ-11 port

사양

BrandAPC
SeriesBack-UPS
ModelBK500BLK
International Version120V
Input Voltage Range98 - 140V
Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
Input ConnectionNEMA 5-15P
VA Rating500 VA
Watts300 Watts
Output Voltage120V
Output Frequency50/60Hz +/- 3 Hz
Outlets6
Outlet Type(3) NEMA 5-15R (Battery Backup)
(3) NEMA 5-15R (Surge Protection)
Battery TypeSealed Lead Acid
Battery Recharge Time8 hour(s)
Battery ReplaceableRBC2, RBC2J
AlarmsAlarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Interface PortDB-9 RS-232, USB
Data Line ProtectionAnalog phone line for phone/fax/modem/DSL (RJ-11 connector)
Surge Energy Rating480 Joules
Dimensions6.50" x 3.58" x 11.18" (H x W x D)
Weight13.82 lbs.
배송 무게6.53 kg
포장 크기358 × 251 × 183 mm

이 상품에 대한 질문

How much desk or floor space does the 4-inch-wide by 11-inch-deep unit need?

The UPS measures 4 inches wide by 11 inches deep by 7 inches high, so allow at least that footprint plus a few inches of clearance for the 6-foot cord and ventilation.

Which outlets should I plug my computer and monitor into, and what does the USB cable do?

Connect critical devices to the three NEMA 5-15R outlets marked Battery Backup; use the other three for surge-only loads. The USB link lets the PC monitor battery status and trigger a graceful shutdown.

When and how do I swap the sealed lead-acid battery?

Replace the user-replaceable RBC2 or RBC2J cartridge when runtime drops noticeably — typically after 3 to 5 years. Power off, unplug, open the battery door, disconnect the old pack, insert the new one, and recharge for eight hours.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.