CyberPower OL1K5RTHD 1500VA 1350W UPS 2U Rack Tower 8 Outlets NEMA 5-15P

SKU CH-WMGW-C738Z MPN OL1K5RTHD

Double-conversion sine-wave UPS delivers 1500 VA and 1350 W through eight NEMA 5-15R outlets in a 2U rack-tower form factor

  • International Version120V
  • Input Voltage Range100 - 125V
  • Input Frequency40 - 70 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating1500 VA
  • Watts1350 Watts
  • Double-conversion topology delivers clean sine-wave output
  • 9 power factor provides 1350 W from 1500 VA rating
  • Eight NEMA 5-15R outlets support multiple devices
  • 2U rack-tower form factor fits dense installations
  • User-configurable output voltage 100-125 VAC ±2%

Double-Conversion 1500VA UPS

The CyberPower OL1K5RTHD is a new 2U rack-tower battery backup that delivers 1500 VA and 1350 W through double-conversion topology. It accepts 100 to 125 V input at 40 to 70 Hz and provides a pure sine-wave output configurable to 100, 110, 115, 120 or 125 VAC within 2%.

Eight NEMA 5-15R Outlets

Eight NEMA 5-15R receptacles supply protected power to connected equipment. A NEMA 5-15P input cord plugs into standard 120 V circuits. A serial interface port enables basic monitoring and management through compatible software. Surge protection is rated at 710 joules.

12.5-Minute Half-Load Runtime

Sealed lead-acid batteries provide 12.5 minutes of runtime at half load and 4 minutes at full load, then recharge to 90% in 4 hours. Batteries are user-replaceable. The unit operates from 32 to 104 °F and stores from 5 to 113 °F in 0 to 90% non-condensing humidity. It is not suited for loads exceeding 1350 W or for installations requiring extended runtime beyond the rated minutes.

주요 특징

  • Double-conversion topology delivers clean sine-wave output
  • 9 power factor provides 1350 W from 1500 VA rating
  • Eight NEMA 5-15R outlets support multiple devices
  • 2U rack-tower form factor fits dense installations
  • User-configurable output voltage 100-125 VAC ±2%

사양

BrandCyberPower
ModelOL1K5RTHD
International Version120V
Input Voltage Range100 - 125V
Input Frequency40 - 70 Hz
Input ConnectionNEMA 5-15P
VA Rating1500 VA
Watts1350 Watts
Output Voltage100/110/115/120/125 VAC +/- 2% (configurable)
Outlets8
Outlet Type8 x NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run Time12.5 minutes / 4 minutes Runtime (half/full)
Battery Recharge Time4 Hours (0% to 90% charged)
Battery ReplaceableYes
AlarmsBattery Mode
Low Battery
Overload
UPS Fault
Interface PortSerial
ApprovalsUL1778
CSA C22.2 No.107.3
FCC Part 15 Class B
Rackmountable2U
Surge Energy Rating710 Joules
ProtectionUPS Output Cut Off Immediately or Input Fuse / Circuit Breaker Protection
TemperatureOperating Temperature: 32 - 104 °F (0 - 40 °C)
Storage Temperature: 5 - 113 °F (-15 - 45 °C)
HumidityOperating Relative Humidity: 0 - 90 % (non-condensing)
Storage Relative Humidity: 0 - 95% (non-condensing)
Dimensions3.4" x 17.05" x 14.96"
Weight37.26 lbs.
배송 무게20.70 kg
포장 크기560 × 480 × 240 mm

이 상품에 대한 질문

How often will the sealed lead-acid battery need replacing?

The battery is user-replaceable and recharges from empty to 90 percent in 4 hours; typical sealed lead-acid cells last three to five years before capacity drops below useful runtime.

At full 1350-watt load the unit runs for only 4 minutes — what stops me from drawing more?

The double-conversion inverter is rated for 1500 VA and 1350 W; an overload alarm sounds and the output cuts off immediately if that limit is exceeded.

How much heat and noise does the 2U rack tower produce during all-day operation?

Operating temperature range is 32 to 104 °F with 0 to 90 percent non-condensing humidity; the unit meets UL 1778 and FCC Class B limits for audible noise and emissions.