저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

DELL

DELL PowerEdge R430 1U rack server E5-2630v3 2.4GHz 24GB DDR4 3x300GB SAS H730

SKU CH-ZBXB-ZSX69

1U rack server with Xeon E5-2630v3 2.4GHz, 24GB DDR4, three 300GB SAS drives and H730 RAID controller

  • TypeRack
  • Rack Height1U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 24GB

HDD 3 x 300GB

  • 1U rack density fits tight data-centre rows
  • Intel Xeon E5-2630v3 eight-core 2.4 GHz handles multi-threaded workloads
  • 24 GB DDR4 memory across 12 DIMM slots supports virtualisation density
  • Three 300 GB 15K SAS drives on PERC H730 RAID deliver fast redundant storage
  • Redundant 550 W hot-swap power supply maintains uptime during module replacement

Dense 1U compute node

The Dell PowerEdge R430 fits a single Xeon E5-2630v3 eight-core processor running at 2.4 GHz and 24 GB of DDR4 memory into a 1U rack chassis. It targets departments that need reliable application hosting or virtualisation density without the depth of larger servers. The H730 RAID controller manages three 300 GB 15K SAS drives with support for RAID 0, 1, 5, 6, 10, 50 and 60 across up to eight 2.5-inch hot-plug bays.

Redundant cooling and power

A single 550 W redundant hot-swap power supply feeds the system while four 1 GbE ports handle network traffic. The 1U form factor uses front-to-rear airflow designed for standard rack cabinets. Installed memory occupies 24 GB across the twelve DDR4 DIMM slots, leaving room for expansion up to the platform maximum of 384 GB when a second processor is added.

Sustained workload behaviour

Under continuous load the eight cores and sixteen threads maintain 2.4 GHz while the H730 controller sustains SAS throughput across the configured RAID array. The 1U chassis limits maximum drive count to eight bays and PCIe expansion to two 3.0 slots, so workloads requiring larger local storage or multiple accelerators will need external enclosures or a taller server. Remote management runs on iDRAC8 Express with optional Enterprise upgrades.

주요 특징

  • 1U rack density fits tight data-centre rows
  • Intel Xeon E5-2630v3 eight-core 2.4 GHz handles multi-threaded workloads
  • 24 GB DDR4 memory across 12 DIMM slots supports virtualisation density
  • Three 300 GB 15K SAS drives on PERC H730 RAID deliver fast redundant storage
  • Redundant 550 W hot-swap power supply maintains uptime during module replacement

사양

BrandDELL
SeriesPowerEdge
ModelPowerEdge R430
TypeRack
Rack Height1U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon
MAX Processors2
ChipsetIntel C610
Installed Memory Size24GB
Memory TypeDDR4
Max Memory Capacity24GB
Memory Features12 DIMM slots, 6 per processor. (4GB/8GB/16GB/32GB DDR4 up to 2400MT/s, actual memory speed dependent on the processor capability).
Number of Memory Slots12
Storage ControllerDell Perc H730 Controller
HDD InterfaceSAS
SSD (Installed)No
Raid LevelRAID 0/1/5/6/10/50/60
Max HDD Capacity16TB
Media DrivesDVD ROM
GPU TypeMatrox G200
Video Memory8MB
Remote ManagementiDRAC8 with Lifecycle Controller, iDRAC8 Express (default), iDRAC8 Enterprise (upgrade) 8GB vFlash media (upgrade), 16GB vFlash media (upgrade)
LAN Ports4 x Ports
Expansion Slots2 PCIe 3.0
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight40.0000LBS

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How do I install the 300GB SAS drives into the 2.5-inch hot-plug bays, and what step is often missed?

Slide each drive into an empty bay until the carrier clicks, then verify the H730 controller detects all three drives in the RAID BIOS before creating a virtual disk.

Which components will need replacement first during long-term operation?

The three 15K SAS drives and the single 550W power supply are the primary field-replaceable units; memory DIMMs and the DVD-ROM are rarely swapped.

What thermal or power limit appears first when the E5-2630v3 runs at full load continuously?

The single 550W redundant power supply caps total system draw, so sustained CPU turbo across all eight cores may throttle before the 1U chassis airflow limit is reached.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.