저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

HP

HP ProLiant DL360 Gen9 8-bay SFF Xeon E5-2670 v3 12C 2.3GHz 96GB DDR4 B140i

SKU CH-MVSR-JB7PY

1U rack server with single 12-core Xeon E5-2670 v3 at 2.3 GHz, 96 GB DDR4, B140i SATA RAID and eight 2.5-inch bays

  • TypeRack
  • Rack Height1U
  • Redundant Hot-swap PowerYes
  • CPU TypeIntel Xeon E5 v3
  • MAX Processors2
  • ChipsetIntel C610

Installed Memory Size 96GB

HDD None

  • 12-core Xeon at 2.3 GHz handles heavy workloads
  • 96 GB DDR4 ECC memory supports large datasets
  • B140i controller enables RAID 0, 1, 5, 10 on SATA drives
  • Dual 500 W hot-swap power supplies keep the server running
  • 1U rack chassis with eight 2.5-inch bays fits tight spaces

Dense 1U rack server for virtualised workloads

The HP ProLiant DL360 Gen9 fits a single Intel Xeon E5-2670 v3 twelve-core processor at 2.3 GHz and 96 GB of DDR4 ECC memory into a 1U chassis. Eight 2.5-inch small-form-factor bays provide internal storage density, while dual 500 W hot-swap power supplies deliver redundancy. The integrated B140i controller handles RAID 0, 1, 5 and 10 for SATA drives. A Matrox G200 graphics chip with 16 MB video memory supplies basic console output.

Suits teams consolidating VMs on a budget.

This configuration targets organisations that need maximum core count and memory capacity in minimal rack space for virtualisation, web hosting or light database tasks. Buyers who require hardware RAID with cache protection or who must boot from SAS drives should look elsewhere, because the B140i software RAID supports SATA only. The single-socket layout also limits total cores to twelve, so heavily threaded HPC jobs will need a dual-processor build.

B140i software RAID limited to SATA drives

The onboard B140i controller provides RAID 0, 1, 5 and 10 exclusively for SATA devices; it does not support SAS or other protocols. Eight SFF bays accept 2.5-inch SATA SSDs or HDDs, and two drive trays with screws are included. If your storage plan depends on SAS disks or a hardware RAID card with battery-backed cache, this server will not meet that requirement.

주요 특징

  • 12-core Xeon at 2.3 GHz handles heavy workloads
  • 96 GB DDR4 ECC memory supports large datasets
  • B140i controller enables RAID 0, 1, 5, 10 on SATA drives
  • Dual 500 W hot-swap power supplies keep the server running
  • 1U rack chassis with eight 2.5-inch bays fits tight spaces

사양

BrandHP
SeriesProLiant
ModelProliant DL360 G9
TypeRack
Rack Height1U
Redundant Hot-swap PowerYes
CPU TypeIntel Xeon E5 v3
MAX Processors2
ChipsetIntel C610
Installed Memory Size96GB
Memory TypeDDR4
Max Memory Capacity96GB
Memory Features24 DIMM slots, 12 per processor. (4GB/8GB/16GB/32GB/64GB DDR4 up to 2400MT/s ECC Registered, actual memory speed dependent on the processor capability).
Number of Memory Slots24
Storage ControllerB140i Software RAID
SSD (Installed)No
Raid LevelRAID 0/1/5/10
Media DrivesNone
GPU TypeMatrox G200
Video Memory16MB
Remote ManagementiLO Management (standard).
LAN Ports4 x Ports
Expansion SlotsPrimary Riser: 2 PCIe 3.0 Slots (1 & 2) available: 1x Full-Height Half Length, 1x Half-Lenth Half Height. Optional PCIe 3.0 slot 3 - Full-Height Half Height (Secondary PCIe Riser and dual CPU required).
Operating SystemNo
Compatible/Certified OSMicrosoft Windows Small Business Server 2011/2008, Microsoft Windows Server 2008 R2 SP1/SP2, Microsoft Windows HPC Server 2008 R2, Novell SUSE Linux Enterprise Server, Red Hat Enterprise Linux, Oracle Solaris
Weight63.0000LBS

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How much power do the two 500W redundant supplies draw when the server runs all day?

The server ships with two 500W hot-swap power supplies in a redundant configuration. Actual draw depends on workload, but the units are rated at 500W each and share the load.

Which drives must I supply myself for the B140i controller to work?

The B140i Software RAID supports SATA only. You must provide 2.5-inch SATA drives; the chassis includes two drive trays with screws but no drives are installed.

Will my existing SAS drives work in the 8-bay SFF backplane?

The backplane accepts 2.5-inch drives, but the installed B140i controller is SATA only. SAS drives will not be recognised unless you add a supported SAS RAID controller.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.