저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

Tripp Lite

Tripp Lite SMART1200XLHG 1000 VA 750 W Medical UPS

SKU CH-YVH3-2T6X0 MPN SMART1200XLHG

Medical-grade tower UPS delivers 1000 VA / 750 W with four hospital-grade outlets and 10-minute full-load runtime

  • Input Voltage Range120V
  • VA Rating1000 VA
  • Watts750 Watts
  • Output VoltageLINE MODE: Sine wave line voltage 120V (-18% / +8%) BATTERY
  • Outlets4
  • Outlet TypeNEMA 5-15R-HG Hospital-Grade
  • Medical-grade UL 60601-1 certification protects patient-care equipment
  • 1000 VA line-interactive topology keeps output at 120 V from 81 to 143 V input
  • Four hospital-grade NEMA 5-15R-HG outlets power critical devices safely
  • 750 W capacity runs full load for 10 minutes and half load for 28 minutes
  • RS-232 and USB ports enable remote monitoring and graceful shutdown

Medical-grade battery backup for patient-care

The Tripp Lite SMART1200XLHG is a 1000 VA line-interactive UPS tested to UL 60601-1 for use in patient point-of-care settings. It delivers 750 W through four hospital-grade NEMA 5-15R-HG outlets. The unit accepts 120 V input and maintains nominal output across an 81 to 143 V range.

Tower form factor with standard data ports

Place the tower on a stable surface and connect the included RS-232 or USB cable to a host computer for power-management software. The four HG outlets accept standard medical-grade plugs without adapters. Audible alarms signal power failure, overload and low battery with distinct beep patterns.

10 minutes of runtime at full 1000 VA load

At maximum rated load the internal VRLA batteries provide 10 minutes of backup; at half load the runtime extends to 28 minutes. Recharge to 90 % capacity takes 2 to 4 hours. The 480 J surge rating supplements the voltage-regulation circuitry.

주요 특징

  • Medical-grade UL 60601-1 certification protects patient-care equipment
  • 1000 VA line-interactive topology keeps output at 120 V from 81 to 143 V input
  • Four hospital-grade NEMA 5-15R-HG outlets power critical devices safely
  • 750 W capacity runs full load for 10 minutes and half load for 28 minutes
  • RS-232 and USB ports enable remote monitoring and graceful shutdown

사양

BrandTRIPP LITE
SeriesSmartPro XL
ModelSMART1200XLHG
Input Voltage Range120V
VA Rating1000 VA
Watts750 Watts
Output VoltageLINE MODE: Sine wave line voltage 120V (-18% / +8%)
BATTERY MODE: PWM sine wave output 115V +/-5%
Outlets4
Outlet TypeNEMA 5-15R-HG Hospital-Grade
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull load runtime: 10 minutes (1000 VA)
Half load runtime: 28 minutes (500 VA)
Battery Recharge Time2 - 4 hour(s) to 90%
Alarms3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone)
Interface PortRS-232, USB
ApprovalsTested to UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), Class A (Emissions)
Surge Energy Rating480 Joules
FeaturesApplications
UL 60601-1 listed UPS provides ultimate safety and reliability for patient point of care solutions, telemedicine, nurse's stations, wireless communications systems, electronic prescribing applications, medical imaging and mission critical equipment. Not recommended for life support applications.
Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed medical electrical equipment is required
Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression
Dimensions12.50" x 7.50" x 9.50"
Weight45.20 lbs.
배송 무게21.80 kg
포장 크기470 × 340 × 310 mm

이 상품에 대한 질문

How can I verify the SMART1200XLHG is working correctly after installation?

The unit runs a self-test on start-up and the three-function audible alarm confirms status: four short beeps every 10 seconds mean battery mode, continuous short beeps signal overload, and a continuous tone warns of low battery.

What ships with the SMART1200XLHG and what must I purchase separately?

The UPS includes a hospital-grade NEMA 5-15P input cord and four NEMA 5-15R-HG outlets; RS-232 and USB cables for monitoring are not included and must be bought separately.

Which capacity of the SmartPro XL medical UPS should I choose for my load?

This model delivers 1000 VA / 750 W with 10 minutes runtime at full load or 28 minutes at half load (500 VA); select it when your connected equipment stays within 750 W.