Tripp Lite
Tripp Lite PDUMNV20HV2LX PDU 3.3/3.7 kW 208/230V 18 C13 2 C19 LX
Monitored 0U PDU delivers 3.3/3.7 kW at 208/230V with 18 C13 and 2 C19 outlets, built-in LX interface and digital ammeter
- TypeMonitored
- Rack Size0U
- StyleVertical
- CertificationsTested to UL60950-1:2007, IEC60950-1: 2005 (USA), CAN/CSA-C2
- ROHSYes
- Package IncludesPDUMNV20HV2LX 3.3/3.7kW Single-Phase Monitored PDU Built-in
- Monitors power draw in real time via digital ammeter
- 20 outlets (18 C13, 2 C19) with plug-lock inserts prevent accidental disconnects
- Built-in LX Platform interface enables 24/7 remote monitoring access
- 3/3.7 kW capacity at 208/230V supports high-density rack deployments
- 0U vertical design fits 35.5" rack height without consuming rack units
Monitored PDU for rack power distribution
The Tripp Lite PDUMNV20HV2LX is a single-phase monitored power distribution unit rated at 3.3 kW at 208 V or 3.7 kW at 230 V. It provides 20 outlets — 18 C13 and 2 C19 — for server and network equipment in data centres and rack environments.
Upgrade from basic unmonitored strips
This unit replaces non-metered power strips when real-time load visibility is required. The built-in digital ammeter and LX Platform interface enable remote monitoring 24/7, making the jump worthwhile for teams that need to track circuit utilisation without additional sensors.
0U vertical mounting with plug-lock inserts
Installation uses the included 0U vertical brackets and hardware in a standard rack. The 10.0 ft detachable cord with NEMA L6-20P and C20 inlet connects to the supply, while 20 supplied plug-lock inserts secure C13 and C19 cords against accidental disconnection.
Pluspunten
- Monitors power draw in real time via digital ammeter
- 20 outlets (18 C13, 2 C19) with plug-lock inserts prevent accidental disconnects
- Built-in LX Platform interface enables 24/7 remote monitoring access
- 3/3.7 kW capacity at 208/230V supports high-density rack deployments
- 0U vertical design fits 35.5" rack height without consuming rack units
Specificaties
| Brand | Tripp Lite |
|---|---|
| Model | PDUMNV20HV2LX |
| Type | Monitored |
| Rack Size | 0U |
| Style | Vertical |
| Certifications | Tested to UL60950-1:2007, IEC60950-1: 2005 (USA), CAN/CSA-C22.2 NO. 60950-1-07 (Canada), CE IEC60950-1:2005, EN55022:2010+2011, EN55024:2010 (International), FCC Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant |
| ROHS | Yes |
| Package Includes | PDUMNV20HV2LX 3.3/3.7kW Single-Phase Monitored PDU Built-in LX Platform interface Detachable NEMA L6-20P to C19 power cord, 10.0 Feet Configuration cable 20 x Plug-lock inserts Rack-mounting hardware PDUMVROTATEBRKT mounting bracket accessory Owner's manual |
| Input Voltage | 208V, 230V |
| Maximum Input Current | 20A |
| Input Connector(s) | NEMA L6-20P; IEC-320 C20 |
| Cord Length | 10.0 Feet |
| Output Voltage | 208V, 230V |
| Output Frequency | 50/60Hz |
| Output Connector(s) | 18 x C13, 2 x C19 |
| Operating Relative Humidity | 5 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -15 - 60 Degree Celcius |
| Storage Relative Humidity | 5 - 95% |
| Features | Distributes and Monitors Network-Grade AC Power 18 C13 and 2 C19 Outlets Distribute AC Power Digital Ammeter Built-In LX Platform Interface Broad Communications Compatibility Essential Safety Features Easy 0U Installation in EIA-Standard 19.0" Racks TAA-Compliant |
| Dimensions | 2.20" x 1.85" x 35.50" |
| Weight | 6.50 lbs. |
| Verzendgewicht | 5.22 kg |
| Pakketafmetingen | 1067 × 157 × 114 mm |
Vragen over dit artikel
How much vertical rack space does the 35.5-inch 0U PDU require for mounting?
The unit mounts in 0U vertical space, using the included rack-mounting hardware along the side of a standard rack without consuming horizontal rack units.
Which input connector must be used with the detachable 10.0-foot cord for a 208/230V 20A supply?
Connect the supplied NEMA L6-20P plug to a matching L6-20R receptacle; the C20 inlet on the PDU accepts the cord's C19 end.
When should the digital ammeter reading be checked to verify balanced loading across the 18 C13 and 2 C19 outlets?
Check the ammeter after initial power-up and whenever equipment is added or removed to ensure the total load stays below the 20A input rating.