Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.

Favoriete artikelen Inloggen

Vertiv

Vertiv Liebert AS5B0NCVGNNXLKB 10kVA Scalable to 15kVA N+1 208V Split Phase Modular UPS

SKU CH-FAPV-5SE5Q MPN AS5B0NCVGNNXLKB

Modular 10 kVA online UPS scales to 15 kVA N+1 with five minutes full-load runtime and hot-swappable VRLA batteries

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating10 kVA
  • Watts9 kW
  • Scalable to 15 kVA N+1 for future growth
  • Online double-conversion topology protects critical loads
  • Five minutes runtime at full load
  • Hot-swappable modules enable maintenance without downtime
  • LCD status display gives instant operational visibility

Scalable 10 kVA Split-Phase UPS

The Vertiv Liebert AS5B0NCVGNNXLKB is a 10 kVA online double-conversion UPS that scales to 15 kVA in an N+1 redundant frame. It accepts 200/100 through 240/120 VAC split-phase input and delivers the same selectable output voltages. The unit mounts in a rack or tower and ships with a factory-installed SNMP web card for network management.

Sustained Load Runtime and Expansion

At full 9 kW load the internal valve-regulated lead-acid batteries provide five minutes of runtime; at half load the reserve extends to fifteen minutes. The modular architecture allows hot-swappable power modules so capacity can be added or a failed module replaced without dropping the connected load. Operating temperature range is 0 °C to 40 °C with humidity tolerance up to 95 % non-condensing.

Five-Minute Full-Load Battery Reserve

The decisive specification is the five-minute runtime at the full 9 kW rating, which determines whether the UPS can bridge the gap to generator start or graceful shutdown in your environment. If the application requires a longer battery window at full load, this model will not meet that need.

Pluspunten

  • Scalable to 15 kVA N+1 for future growth
  • Online double-conversion topology protects critical loads
  • Five minutes runtime at full load
  • Hot-swappable modules enable maintenance without downtime
  • LCD status display gives instant operational visibility

Specificaties

BrandVertiv
SeriesLiebert
ModelAS5B0NCVGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating10 kVA
Watts9 kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 15 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions27" x 17" x 32"
Weight470 lbs.
Verzendgewicht213.19 kg
Pakketafmetingen813 × 813 × 432 mm

Andere versies van dit model

Nog 5 in dezelfde serie

Dezelfde familie, met ander geheugen, andere koeler of kloksnelheid — vergelijk voordat u beslist.

Vragen over dit artikel

How much heat does the 9 kW output generate when the UPS runs continuously at full load?

The unit operates between 32°F and 104°F and weighs 470 lbs, so adequate airflow in the rack or room is needed to dissipate the heat produced by 9 kW continuous output.

What electrical service must the site already provide for the 4-wire L-L-N-G input?

A 208/120 VAC three-phase service with neutral and ground, capable of supplying the 10 kVA input within the 200–240 VAC range and 40–70 Hz frequency window.

Can the factory-installed SNMP/Webcard manage the UPS alongside older network gear that only supports 10/100 Mbps Ethernet?

Yes, the SNMP/Webcard communicates over standard Ethernet and will interoperate with legacy 10/100 switches without requiring a dedicated management network.

Ook in deze afdeling

Klanten vergeleken ook

Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.