BFKK 3U Rackmount Server Chassis EATX/ATX/MATX 4x5.25 6x3.5 Top/Side Cooling
- Rackmount
Aceptamos criptomonedas — así, las criptos que usted tiene pueden comprar hardware real.Pague en cripto y gástela en hardware real. Envío asegurado gratis a nivel mundial a partir de $399. Cajas neutras, sin marca, enviadas desde Alemania.Envío asegurado gratis a partir de $399. Su cotización queda bloqueada 30 minutos en cuanto se abre el pago.Cotización bloqueada 30 minutos. Todos los artículos vienen sellados, con el número de serie verificado y cubiertos por una garantía de 24 meses.Sellado, con 24 meses de garantía.
Comtrol Corporation
Adds eight RS-232/422/485 serial ports via PCI-X with software-selectable 460Kbps data rates and low-profile fit for 2U servers
The Comtrol RocketPort Infinity 30020-5 is an 8-port serial header adapter that adds RS-232/422/485 connectivity to servers through a PCI or PCI-X slot. It is aimed at IT teams and system integrators who need to connect multiple serial devices such as industrial equipment, modems or console ports in rackmount or standard server chassis. The low-profile bracket fits 2U rackmount servers as well as full-height systems. The card uses Comtrol Unity ASIC technology to operate on the 66 MHz bus available on PCI-X platforms.
The card requires a 32-bit or 64-bit 3.3 volt PCI or PCI-X expansion slot and communicates at up to 460 Kbps per port through software-selectable RS-232/422/485 interfaces. An external four-port or eight-port interface module must be purchased separately to complete the connection. Physical dimensions are 2.6 inches in height by 4.7 inches in width, so the slot area must accommodate that footprint. No other bus type or voltage is supported.
This adapter suits administrators expanding serial I/O on legacy or current servers that still provide 3.3 volt PCI or PCI-X slots and can accept a low-profile card. It is not for builders whose systems only offer PCI Express, USB or other modern interconnects, nor for installations that need the external cable assembly included in the box. Buyers requiring more than eight serial ports or higher per-port throughput will need a different solution.
| Brand | Comtrol |
|---|---|
| Model | 30020-5 |
| Type | Serial Header Adapter |
| External Ports | 8 x Serial Ports |
| Features | This RocketPort INFINITY card delivers up to 8-ports of additional in-server serial connectivity via a four or eight-port external interface that is purchased separately. Data communication of 460Kbps is connected through RS-232/422/485 software-selectable ports. The serial adapter card is a low profile design suitable for use in both standard servers and 2U rackmount servers. Product is fully compatible with systems that have 32 or 64 bit 3.3 volt PCI and PCI-X expansion slots. The INFINITY design utilizes the Comtrol Unity ASIC technology that takes full advantage of the 66 MHz BUS |
| Dimensions | 2.6" Height x 4.7" Width |
| Peso de envío | 0.09 kg |
| Dimensiones del paquete | 152 × 102 × 25 mm |
Each of the eight ports can reach 460 Kbps in RS-232, RS-422 or RS-485 mode, software-selectable per port.
The card fits 32-bit or 64-bit 3.3 V PCI and PCI-X slots and runs at the 66 MHz PCI-X bus speed.
Yes, the board measures 2.6 inches high by 4.7 inches wide and is designed for both standard and 2U servers.
También en este pasillo
Mismo estante, mismo pago — ocho criptomonedas y un tipo de cambio fijado 30 minutos.
Lo que usted paga, y la moneda en la que lee los precios.
Se envía desde su billetera al finalizar la compra
Solo informativo — el catálogo está en dólares
Ninguna moneda coincide.
Elija el idioma en el que el sitio le habla.
Ningún idioma coincide.
¿Es nuevo aquí?
¿Ya tiene una?
No existe ningún restablecimiento automático: esta tienda no envía correos electrónicos, así que no hay ningún enlace de un solo uso que solicitar. Deje la dirección asociada a la cuenta y se atenderá de forma manual.
Solicitud registrada
No hay nada de camino a su bandeja de entrada: esta tienda no envía correos en absoluto. Alguien se encarga de esto manualmente.
¿La recordó?