CyberPower
CyberPower OL3KRM 3000VA 2400W UPS 6x5-20R 1xL5-30R
Double-conversion online UPS delivers 2400 W from a rack-mountable chassis with six NEMA 5-20R and one NEMA L5-30R outlet
- International Version120V
- Input Voltage Range100 - 125V
- Input Frequency40 - 70 Hz
- Input ConnectionNEMA L5-30P
- VA Rating3000 VA
- Watts2400 Watts
- Online double-conversion topology delivers pure sine-wave power
- Configurable 100/110/115/120/125 V output matches sensitive equipment needs
- Seven outlets: six NEMA 5-20R plus one NEMA L5-30R for versatile rack connections
- 2 min runtime at full load / 7.5 min at half load protects critical workloads
- User-replaceable RB1270X4K battery cartridge extends service life without downtime
Double-Conversion Online UPS
The CyberPower OL3KRM is a rack-mountable uninterruptible power supply that uses double-conversion online topology. It delivers 3000 VA and 2400 W of clean sine-wave output to servers, networking gear or storage arrays that require continuous power conditioning. The unit accepts 100 to 125 VAC input and provides configurable output at 100, 110, 115, 120 or 125 VAC.
Rack Integration and Connectivity
Designed for standard racks, the UPS connects to a 30 A branch circuit through a NEMA L5-30P inlet. Seven rear outlets include six NEMA 5-20R receptacles and one NEMA L5-30R for higher-draw equipment. Management is handled via USB and serial ports, while audible alarms signal battery mode, low battery, overload and UPS fault conditions.
Battery Capacity and Limits
Sealed lead-acid batteries provide 2.2 minutes of runtime at full 2400 W load and 7.5 minutes at half load. Recharge from empty to 90 percent takes four hours using the RB1270X4K replacement kit. Overload protection bypasses at 102 to 130 percent for twelve seconds and shuts down above 130 percent on battery, so sustained loads beyond the rated wattage are not supported.
Puntos fuertes
- Online double-conversion topology delivers pure sine-wave power
- Configurable 100/110/115/120/125 V output matches sensitive equipment needs
- Seven outlets: six NEMA 5-20R plus one NEMA L5-30R for versatile rack connections
- 2 min runtime at full load / 7.5 min at half load protects critical workloads
- User-replaceable RB1270X4K battery cartridge extends service life without downtime
Especificaciones
| Brand | CyberPower |
|---|---|
| Series | Essential Online UPS |
| Model | OL3KRM |
| International Version | 120V |
| Input Voltage Range | 100 - 125V |
| Input Frequency | 40 - 70 Hz |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000 VA |
| Watts | 2400 Watts |
| Output Voltage | 100/110/115/120/125 VAC +/- 2% (configurable) |
| Outlets | 7 |
| Outlet Type | 6 x NEMA 5-20R 1 x NEMA L5-30R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 2.2 min Full Load / 7.5 min Half Load |
| Battery Recharge Time | 4 Hours (0% to 90% charged) |
| Battery Replaceable | RB1270X4K |
| Alarms | Battery Mode Low Battery Overload UPS Fault |
| Interface Port | USB, Serial |
| Approvals | UL 1778 CSA C22.2 NO.107.3 FCC Part 15 Class A |
| Rackmountable | Yes |
| Surge Energy Rating | 710 Joules |
| Protection | UPS Output Cut Off Immediately or Input Fuse Circuit Breaker Protection Overload Protection: Line Mode: 102% to 130% load for 12s - bypass Line Mode: 131% to 150% load for 2 s - bypass >150% load 300ms -no output Battery Mode: 102% to 130% load for 12 s - shutdown Battery Mode: >130% for 2 s -shutdown Bypass Mode: 102% to 110% warning Bypass Mode: 111% to 130% load for 5min - no output Bypass Mode: 131% to 150% 16s - no output >150% for 300ms - no output |
| Temperature | Operating Temperature: 32 - 104 °F (0 - 40 °C) Storage Temperature: 5 - 113 °F (-15 - 45 °C) |
| Humidity | Operating Relative Humidity: 0 - 0.9 % (non-condensing) Storage Relative Humidity: 0 - 0.95% (non-condensing) |
| Dimensions | 3.41" x 17.05" x 18.31" |
| Weight | 48.28 lbs. |
| Peso de envío | 25.70 kg |
| Dimensiones del paquete | 570 × 560 × 240 mm |
Preguntas sobre este artículo
How long will the battery last at full 2400W load before shutdown?
The sealed lead-acid pack delivers 2.2 minutes at full load and 7.5 minutes at half load before the low-battery alarm triggers shutdown.
What is the typical fan noise and heat output when the unit runs continuously in a 40°C rack?
The double-conversion design operates up to 40°C with non-condensing humidity; fan speed ramps with load and temperature, so sustained full-load operation will produce noticeable airflow and warmth.
Which input plug and circuit must already be installed for this UPS to power on?
A NEMA L5-30P receptacle on a 30 A branch circuit is required to connect the UPS input.
También en este pasillo
Los clientes también compararon
Mismo estante, mismo pago — ocho criptomonedas y un tipo de cambio fijado 30 minutos.
Black Box Corporation DisplayPort to DVI Fibre Optic Cable 15 ft 4.5 m 1.35 GB/s
- Consumer Electronics