Vertiv
Vertiv PSI5-1100RT120 UPS 1100VA 990W 120V 2U Rack/Tower
Line-interactive UPS with pure sine-wave output delivers 990 W from six NEMA 5-15R outlets and fits 2U rack or tower
- International Version120V
- Input Voltage Range75-146VAC
- Input Frequency55~65Hz (57~63Hz Battery to Normal comeback)
- Input ConnectionNEMA 5-15
- VA Rating1100VA
- Watts990W
Option PSI5-1100RT120
- PSI5-1100MT120
- PSI5-1100RT120
- PSI5-1500MT120
- PSI5-1500RM1201U
- PSI5-1500RT120
- PSI5-2200RT120
- PSI5-3000RT120
- PSI5-5000RT208
- PSI5-750MT120
- PSI5-800RT120
- PSI5-800RT120N
Les versions barrées existent, mais ne sont pas disponibles ici.
- 9 power factor delivers 990W from 1100VA capacity
- Rotatable LCD readout stays clear in rack or tower orientation
- Pure sine wave output protects active PFC power supplies
- Automatic voltage regulation corrects 75-146VAC input without battery drain
- Hot-swappable battery module enables replacement without powering down
Compact 2U Rack/Tower UPS
The Vertiv Liebert PSI5-1100RT120 is a line-interactive uninterruptible power supply rated at 1100VA and 990W with a .9 power factor. It accepts 120V input through a NEMA 5-15 plug and delivers pure sine-wave output on battery. Six NEMA 5-15R outlets support active PFC power supplies, networking gear, workstations and point-of-sale systems in edge locations.
Thermals Noise and Efficiency
The unit operates between 32°F and 104°F and stores safely from 5°F to 120°F. Automatic voltage regulation corrects brownouts and over-voltages from 75VAC to 146VAC without using battery capacity. A rotating LCD panel shows real-time status in either rack or tower orientation, and hot-swappable VRLA modules simplify maintenance while the UPS stays online.
Sustained Load Behavior
At full load the battery provides 4.5 minutes of runtime; at half load it extends to 13.5 minutes. Recharge reaches 90 percent capacity in four hours. The 1372-joule surge rating absorbs transient spikes, and the transfer window of 55Hz to 65Hz (57Hz to 63Hz for battery-to-normal return) keeps connected equipment running through unstable utility power.
Points forts
- 9 power factor delivers 990W from 1100VA capacity
- Rotatable LCD readout stays clear in rack or tower orientation
- Pure sine wave output protects active PFC power supplies
- Automatic voltage regulation corrects 75-146VAC input without battery drain
- Hot-swappable battery module enables replacement without powering down
Caractéristiques
| Brand | Liebert |
|---|---|
| Series | PSI5 |
| Model | PSI5-1100RT120 |
| International Version | 120V |
| Input Voltage Range | 75-146VAC |
| Input Frequency | 55~65Hz (57~63Hz Battery to Normal comeback) |
| Input Connection | NEMA 5-15 |
| VA Rating | 1100VA |
| Watts | 990W |
| Output Voltage | 120VAC (100/110/115/125VAC user-configurable) |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load: 4.5 min Half Load: 13.5 min |
| Battery Recharge Time | 4 hours to recover 90% |
| Battery Replaceable | PSI5-24VBATT |
| Approvals | UL 1778, c-UL-us Listed |
| Rackmountable | 2U Rack/Tower |
| Surge Energy Rating | 1372 Joules |
| Temperature | Operating Temperature: 32°-104°F (0°-40°C) Storage Temperature: 5°-120°F (-15° - 50°C) |
| Humidity | 20% to 90% non-condensing |
| Dimensions | 3.5" x 17.2" x 16.1" |
| Weight | 29.5 lbs. |
| Poids d’expédition | 19.64 kg |
| Dimensions du colis | 585 × 582 × 580 mm |
Autres versions de ce modèle
2 de plus dans cette gamme
Même famille, mémoire, ventirad ou fréquence différents — comparez avant de vous décider.
Vertiv PSI5-800RT120N 800VA 720W Line-Interactive UPS 2U Rack/Tower
- 120V
- 75-146VAC
Questions sur cet article
How do I mount the 2U rack/tower UPS and orient the rotatable LCD so it is readable in either position?
Secure the unit in a standard 2U rack space using the included brackets, or place it on a stable surface as a tower; then rotate the LCD module 90° until the display faces the front in your chosen orientation.
Which replacement battery cartridge do I order when the internal VRLA cells reach end of life?
Order the PSI5-24VBATT cartridge; the UPS supports hot-swappable replacement so you can swap the battery without powering down connected equipment.
How long will the UPS sustain a 990 W full load before the battery is depleted?
The unit provides 4.5 minutes of runtime at the full 990 W load, giving enough time to initiate an orderly shutdown.
Également dans ce rayon
Les clients ont aussi comparé
Même rayon, même caisse — huit monnaies et un taux bloqué 30 minutes.
ModMyMods MOD-0002 3/8" ID x 1/2" OD Clear PVC Tubing DIY Cooling
- Clear