我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

Vertiv

Vertiv PSI5-1100RT120 UPS 1100VA 990W 120V 2U Rack/Tower

SKU CH-M610-ADV07 MPN PSI5-1100RT120

Line-interactive UPS with pure sine-wave output delivers 990 W from six NEMA 5-15R outlets and fits 2U rack or tower

  • International Version120V
  • Input Voltage Range75-146VAC
  • Input Frequency55~65Hz (57~63Hz Battery to Normal comeback)
  • Input ConnectionNEMA 5-15
  • VA Rating1100VA
  • Watts990W

Option PSI5-1100RT120

  • PSI5-1100MT120
  • PSI5-1100RT120
  • PSI5-1500MT120
  • PSI5-1500RM1201U
  • PSI5-1500RT120
  • PSI5-2200RT120
  • PSI5-3000RT120
  • PSI5-5000RT208
  • PSI5-750MT120
  • PSI5-800RT120
  • PSI5-800RT120N

被劃上刪除線的選項確實存在,但本站並無供貨。

  • 9 power factor delivers 990W from 1100VA capacity
  • Rotatable LCD readout stays clear in rack or tower orientation
  • Pure sine wave output protects active PFC power supplies
  • Automatic voltage regulation corrects 75-146VAC input without battery drain
  • Hot-swappable battery module enables replacement without powering down

Compact 2U Rack/Tower UPS

The Vertiv Liebert PSI5-1100RT120 is a line-interactive uninterruptible power supply rated at 1100VA and 990W with a .9 power factor. It accepts 120V input through a NEMA 5-15 plug and delivers pure sine-wave output on battery. Six NEMA 5-15R outlets support active PFC power supplies, networking gear, workstations and point-of-sale systems in edge locations.

Thermals Noise and Efficiency

The unit operates between 32°F and 104°F and stores safely from 5°F to 120°F. Automatic voltage regulation corrects brownouts and over-voltages from 75VAC to 146VAC without using battery capacity. A rotating LCD panel shows real-time status in either rack or tower orientation, and hot-swappable VRLA modules simplify maintenance while the UPS stays online.

Sustained Load Behavior

At full load the battery provides 4.5 minutes of runtime; at half load it extends to 13.5 minutes. Recharge reaches 90 percent capacity in four hours. The 1372-joule surge rating absorbs transient spikes, and the transfer window of 55Hz to 65Hz (57Hz to 63Hz for battery-to-normal return) keeps connected equipment running through unstable utility power.

商品特色

  • 9 power factor delivers 990W from 1100VA capacity
  • Rotatable LCD readout stays clear in rack or tower orientation
  • Pure sine wave output protects active PFC power supplies
  • Automatic voltage regulation corrects 75-146VAC input without battery drain
  • Hot-swappable battery module enables replacement without powering down

商品規格

BrandLiebert
SeriesPSI5
ModelPSI5-1100RT120
International Version120V
Input Voltage Range75-146VAC
Input Frequency55~65Hz (57~63Hz Battery to Normal comeback)
Input ConnectionNEMA 5-15
VA Rating1100VA
Watts990W
Output Voltage120VAC (100/110/115/125VAC user-configurable)
Outlets6
Outlet Type6 x NEMA 5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 4.5 min
Half Load: 13.5 min
Battery Recharge Time4 hours to recover 90%
Battery ReplaceablePSI5-24VBATT
ApprovalsUL 1778, c-UL-us Listed
Rackmountable2U Rack/Tower
Surge Energy Rating1372 Joules
TemperatureOperating Temperature: 32°-104°F (0°-40°C)
Storage Temperature: 5°-120°F (-15° - 50°C)
Humidity20% to 90% non-condensing
Dimensions3.5" x 17.2" x 16.1"
Weight29.5 lbs.
出貨重量19.64 kg
包裝尺寸585 × 582 × 580 mm

其他版本

同系列還有 2 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How do I mount the 2U rack/tower UPS and orient the rotatable LCD so it is readable in either position?

Secure the unit in a standard 2U rack space using the included brackets, or place it on a stable surface as a tower; then rotate the LCD module 90° until the display faces the front in your chosen orientation.

Which replacement battery cartridge do I order when the internal VRLA cells reach end of life?

Order the PSI5-24VBATT cartridge; the UPS supports hot-swappable replacement so you can swap the battery without powering down connected equipment.

How long will the UPS sustain a 990 W full load before the battery is depleted?

The unit provides 4.5 minutes of runtime at the full 990 W load, giving enough time to initiate an orderly shutdown.