APC SRT1000RMXLA-NC 1000VA 900W 120V 2U 6x5-15R 480J UPS
- 120V
- 80 - 150V
APC
Double-conversion on-line UPS delivers 3000 VA and 2700 W through nine battery-backed outlets with scalable runtime
Options SRT3000XLA
The APC SRT3000XLA is a 3000 VA double-conversion on-line UPS delivering 2700 watts of continuous power from a 120 volt input. Nine battery-backed outlets include one NEMA L5-30R and eight NEMA 5-20R receptacles for dense rack or tower deployments. It suits network closets, server rooms and edge sites that cannot tolerate any transfer time during utility failure.
Stepping up from a line-interactive design removes the brief switchover gap and adds automatic voltage regulation across a 40 to 70 hertz input range without draining the battery. The jump is worth it when connected loads include sensitive hypervisors, storage arrays or VoIP gear that crash on millisecond interruptions. It is not for buyers who only need basic surge filtering and can accept a short break before battery engagement.
Sealed lead-acid cells provide one to thirty minutes of backup depending on the connected wattage, and recharge in about three hours. The replaceable cartridge uses part number APCRBC152 for tool-less swaps without powering down. At full 2700 watt load the reserve is minimal, so plan external battery packs for extended autonomy. It is not for sites that require hours of runtime without generator support.
| Brand | APC |
|---|---|
| Series | Smart-UPS |
| Model | SRT3000XLA |
| Input Voltage Range | 120 V |
| Input Frequency | 40 - 70 Hz (auto sensing) |
| VA Rating | 3000 VA |
| Watts | 2700 Watts |
| Output Voltage | 120V |
| Output Frequency | 50/60Hz +/- 3 Hz |
| Outlets | 9 |
| Outlet Type | (1) NEMA L5-30R (Battery Backup) (8) NEMA 5-20R (Battery Backup) |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 1 - 30 minutes |
| Battery Recharge Time | 3 hour(s) |
| Battery Replaceable | APCRBC152 |
| Alarms | Audible and visible alarms prioritized by severity |
| Interface Port | RJ-45 Serial, Smart-Slot, USB |
| Approvals | CSA C22.2 No.107.3-05, ENERGY STAR (USA), FCC Part 15 Class A, UL 1778, RoHS Compliant |
| Surge Energy Rating | 340 Joules |
| Features | APC Smart-UPS SRT 3000VA 120V High density, double-conversion on-line power protection with scalable runtime |
| Dimensions | 17.00" x 3.35" x 25.00" |
| Weight | 69.00 lbs. |
| Package Contents | CD with software, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card |
| 配送重量 | 41.73 kg |
| 梱包サイズ | 864 × 610 × 229 mm |
このモデルの他のバージョン
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
The unit measures 17.00 inches wide, 3.35 inches high and 25.00 inches deep, so it occupies 2U of rack height and requires at least 25 inches of usable rack depth plus cable clearance.
Connect the L5-30R input to a dedicated 30 A branch circuit first, then attach the USB cable and install the PowerChute software before powering on the UPS so the management interface registers correctly.
Replace the APCRBC152 cartridge when runtime drops below the 1 to 30 minute range; a full recharge from empty takes 3 hours.
同じ売り場の商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
お支払いに使うコインと、価格表示に使う通貨です。
チェックアウト時にウォレットから送信されます。
表示のみ—カタログの価格は米ドル建てです。
該当する通貨がありません。
サイトの表示言語を選択してください。
一致する言語がありません。
初めてのご利用ですか?
すでにお持ちですか?
自動的な再設定はありません。当店はメールを送信しないため、ワンタイムリンクをお送りすることもできません。アカウントにメールアドレスを残しておいていただければ、担当者が手作業で確認いたします。
リクエストを受け付けました
受信箱に何かが届くことはありません — 当店はメールを一切送信していません。担当者が手作業で確認いたします。
思い出しましたか?