我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

APC

APC SRT3000XLA UPS 3000VA 120V 2700W 9 Outlets

SKU CH-RQTV-PS1Y1 MPN SRT3000XLA

Double-conversion on-line UPS delivers 3000 VA and 2700 W through nine battery-backed outlets with scalable runtime

  • Input Voltage Range120 V
  • Input Frequency40 - 70 Hz (auto sensing)
  • VA Rating3000 VA
  • Watts2700 Watts
  • Output Voltage120V
  • Output Frequency50/60Hz +/- 3 Hz
  • Double-conversion on-line topology delivers clean 120 V output
  • 3000 VA / 2700 W capacity supports dense server loads
  • Nine battery-backup outlets include L5-30R and eight 5-20R
  • Hot-swappable APCRBC152 battery module enables zero-downtime replacement
  • RJ-45 serial, Smart-Slot and USB ports provide flexible management

Purpose-built power protection

The APC SRT3000XLA is a 3000 VA double-conversion on-line UPS delivering 2700 watts of continuous power from a 120 volt input. Nine battery-backed outlets include one NEMA L5-30R and eight NEMA 5-20R receptacles for dense rack or tower deployments. It suits network closets, server rooms and edge sites that cannot tolerate any transfer time during utility failure.

Replaces line-interactive units

Stepping up from a line-interactive design removes the brief switchover gap and adds automatic voltage regulation across a 40 to 70 hertz input range without draining the battery. The jump is worth it when connected loads include sensitive hypervisors, storage arrays or VoIP gear that crash on millisecond interruptions. It is not for buyers who only need basic surge filtering and can accept a short break before battery engagement.

Runtime scales with load

Sealed lead-acid cells provide one to thirty minutes of backup depending on the connected wattage, and recharge in about three hours. The replaceable cartridge uses part number APCRBC152 for tool-less swaps without powering down. At full 2700 watt load the reserve is minimal, so plan external battery packs for extended autonomy. It is not for sites that require hours of runtime without generator support.

商品特色

  • Double-conversion on-line topology delivers clean 120 V output
  • 3000 VA / 2700 W capacity supports dense server loads
  • Nine battery-backup outlets include L5-30R and eight 5-20R
  • Hot-swappable APCRBC152 battery module enables zero-downtime replacement
  • RJ-45 serial, Smart-Slot and USB ports provide flexible management

商品規格

BrandAPC
SeriesSmart-UPS
ModelSRT3000XLA
Input Voltage Range120 V
Input Frequency40 - 70 Hz (auto sensing)
VA Rating3000 VA
Watts2700 Watts
Output Voltage120V
Output Frequency50/60Hz +/- 3 Hz
Outlets9
Outlet Type(1) NEMA L5-30R (Battery Backup)
(8) NEMA 5-20R (Battery Backup)
Battery TypeSealed Lead Acid
Battery Run Time1 - 30 minutes
Battery Recharge Time3 hour(s)
Battery ReplaceableAPCRBC152
AlarmsAudible and visible alarms prioritized by severity
Interface PortRJ-45 Serial, Smart-Slot, USB
ApprovalsCSA C22.2 No.107.3-05, ENERGY STAR (USA), FCC Part 15 Class A, UL 1778, RoHS Compliant
Surge Energy Rating340 Joules
FeaturesAPC Smart-UPS SRT 3000VA 120V
High density, double-conversion on-line power protection with scalable runtime
Dimensions17.00" x 3.35" x 25.00"
Weight69.00 lbs.
Package ContentsCD with software, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card
出貨重量41.73 kg
包裝尺寸864 × 610 × 229 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

What rack depth and height does the SRT3000XLA need to fit in a 17.00" x 25.00" form factor?

The unit measures 17.00 inches wide, 3.35 inches high and 25.00 inches deep, so it occupies 2U of rack height and requires at least 25 inches of usable rack depth plus cable clearance.

Which step is often missed when wiring the NEMA L5-30R input and the eight NEMA 5-20R outlets?

Connect the L5-30R input to a dedicated 30 A branch circuit first, then attach the USB cable and install the PowerChute software before powering on the UPS so the management interface registers correctly.

When should the APCRBC152 battery cartridge be replaced and how long does a full recharge take?

Replace the APCRBC152 cartridge when runtime drops below the 1 to 30 minute range; a full recharge from empty takes 3 hours.