MINUTEMAN EXR1000RT2UNC UPS 1000VA 900W 2U 8 outlets
- 80 to 164VAC (150 -…
- 50/60 Hz, +/- 6 Hz…
MINUTEMAN
Line-interactive UPS delivers 1350 W from a 2U rack or tower chassis with eight NEMA 5-15R outlets, LCD status, USB, DB-9 and SNMP-NV6 network management
Model EXR1500RT2UNC
取り消し線の付いたバージョンは存在しますが、こちらでは取り扱っていません。
The MINUTEMAN EXR1500RT2UNC delivers 1500 VA and 1350 W of battery-backed power in a 2U form factor that fits a rack or stands as a tower. It accepts a wide input window of 80 to 164 VAC and auto-senses 50 or 60 Hz frequency. Eight NEMA 5-15R outlets supply connected equipment while a replaceable BM0087 battery module keeps service simple.
Management interfaces include DB-9, USB and an RJ-45 network port that hosts the supplied SNMP-NV6 card for remote monitoring. A 1 Gbit Ethernet in/out surge circuit protects data lines alongside the 1000 Joule AC surge rating. The unit operates from 0 to 40 °C in up to 95 % non-condensing humidity and carries cULus, FCC Class B, CE, NOM, EnergyStar 2.0 and RoHS2 approvals.
At full load the battery runs for 2.5 minutes and at half load for 9 minutes, giving time for graceful shutdown or generator start. The 2U rack profile suits server rooms and network closets where floor space is limited. Buyers who need longer runtime at full load or higher power capacity should consider larger units.
| Brand | MINUTEMAN |
|---|---|
| Series | EXR Series |
| Model | EXR1500RT2UNC |
| Input Voltage Range | 80 to 164VAC (150 - 271VAC) |
| Input Frequency | 50/60 Hz, +/- 6 Hz auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 1350W |
| Output Voltage | 120VAC: 101 - 136VAC (208VAC: 186 - 236VAC) |
| Outlets | 8 |
| Outlet Type | (8) NEMA 5-15R |
| Battery Run Time | Full/Half Load: 2.5 / 9 minutes |
| Battery Replaceable | BM0087 |
| Interface Port | DB-9, USB, RJ-45 |
| Approvals | cULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B, CE & NOM certified,EnergyStar 2.0, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) |
| Rackmountable | 2U |
| Surge Energy Rating | 1000 Joules |
| Surge Protection | 1Gbit RJ45 Ethernet (in/out) |
| Temperature | 0 to 40°C (+32 to +104°F) |
| Humidity | 0 - 95% Non-Condensing |
| Dimensions | 3.48" x 18.96" x 17.32" |
| Weight | 43 lbs. |
| 配送重量 | 19.96 kg |
| 梱包サイズ | 483 × 439 × 89 mm |
このモデルの他のバージョン
同じファミリーで、メモリ・クーラー・クロックが異なります — 購入前に比較してください。
The DB-9 and USB ports provide local serial or USB management, while the RJ-45 port connects the included SNMP-NV6 network card for remote monitoring and alerts over Ethernet.
The unit measures 3.48" high, 18.96" wide and 17.32" deep, weighs 43 lbs and fits a standard 2U rack opening; rack ears and tower feet are included for either orientation.
Power off the UPS, remove the interface slot cover, insert the SNMP-NV6 card firmly until seated, secure the retaining screws, then power on and configure the card's IP address — the step often missed is assigning a static IP before connecting to the network.
同じ売り場の商品
同じ売り場、同じレジ — 8種類のコインと30分間のレートロック。
お支払いに使うコインと、価格表示に使う通貨です。
チェックアウト時にウォレットから送信されます。
表示のみ—カタログの価格は米ドル建てです。
該当する通貨がありません。
サイトの表示言語を選択してください。
一致する言語がありません。
初めてのご利用ですか?
すでにお持ちですか?
自動的な再設定はありません。当店はメールを送信しないため、ワンタイムリンクをお送りすることもできません。アカウントにメールアドレスを残しておいていただければ、担当者が手作業で確認いたします。
リクエストを受け付けました
受信箱に何かが届くことはありません — 当店はメールを一切送信していません。担当者が手作業で確認いたします。
思い出しましたか?