MINUTEMAN EXR1000RT2UNC UPS 1000VA 900W 2U 8 outlets
- 80 to 164VAC (150 -…
- 50/60 Hz, +/- 6 Hz…
MINUTEMAN
Line-interactive UPS delivers 1350 W from a 2U rack or tower chassis with eight NEMA 5-15R outlets, LCD status, USB, DB-9 and SNMP-NV6 network management
Model EXR1500RT2UNC
취소선으로 표시된 버전은 존재하지만, 이곳에서는 취급하지 않습니다.
The MINUTEMAN EXR1500RT2UNC delivers 1500 VA and 1350 W of battery-backed power in a 2U form factor that fits a rack or stands as a tower. It accepts a wide input window of 80 to 164 VAC and auto-senses 50 or 60 Hz frequency. Eight NEMA 5-15R outlets supply connected equipment while a replaceable BM0087 battery module keeps service simple.
Management interfaces include DB-9, USB and an RJ-45 network port that hosts the supplied SNMP-NV6 card for remote monitoring. A 1 Gbit Ethernet in/out surge circuit protects data lines alongside the 1000 Joule AC surge rating. The unit operates from 0 to 40 °C in up to 95 % non-condensing humidity and carries cULus, FCC Class B, CE, NOM, EnergyStar 2.0 and RoHS2 approvals.
At full load the battery runs for 2.5 minutes and at half load for 9 minutes, giving time for graceful shutdown or generator start. The 2U rack profile suits server rooms and network closets where floor space is limited. Buyers who need longer runtime at full load or higher power capacity should consider larger units.
| Brand | MINUTEMAN |
|---|---|
| Series | EXR Series |
| Model | EXR1500RT2UNC |
| Input Voltage Range | 80 to 164VAC (150 - 271VAC) |
| Input Frequency | 50/60 Hz, +/- 6 Hz auto-sensing |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 1350W |
| Output Voltage | 120VAC: 101 - 136VAC (208VAC: 186 - 236VAC) |
| Outlets | 8 |
| Outlet Type | (8) NEMA 5-15R |
| Battery Run Time | Full/Half Load: 2.5 / 9 minutes |
| Battery Replaceable | BM0087 |
| Interface Port | DB-9, USB, RJ-45 |
| Approvals | cULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B, CE & NOM certified,EnergyStar 2.0, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) |
| Rackmountable | 2U |
| Surge Energy Rating | 1000 Joules |
| Surge Protection | 1Gbit RJ45 Ethernet (in/out) |
| Temperature | 0 to 40°C (+32 to +104°F) |
| Humidity | 0 - 95% Non-Condensing |
| Dimensions | 3.48" x 18.96" x 17.32" |
| Weight | 43 lbs. |
| 배송 무게 | 19.96 kg |
| 포장 크기 | 483 × 439 × 89 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
The DB-9 and USB ports provide local serial or USB management, while the RJ-45 port connects the included SNMP-NV6 network card for remote monitoring and alerts over Ethernet.
The unit measures 3.48" high, 18.96" wide and 17.32" deep, weighs 43 lbs and fits a standard 2U rack opening; rack ears and tower feet are included for either orientation.
Power off the UPS, remove the interface slot cover, insert the SNMP-NV6 card firmly until seated, secure the retaining screws, then power on and configure the card's IP address — the step often missed is assigning a static IP before connecting to the network.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?