MINUTEMAN

MINUTEMAN EXR1500RT2UNC UPS 1.5kVA 1350W 2U Rack/Tower LCD SNMP-NV6

SKU CH-ZBXQ-3A70J MPN EXR1500RT2UNC

Line-interactive UPS delivers 1350 W from a 2U rack or tower chassis with eight NEMA 5-15R outlets, LCD status, USB, DB-9 and SNMP-NV6 network management

  • Input Voltage Range80 to 164VAC (150 - 271VAC)
  • Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
  • Input ConnectionNEMA 5-15P
  • VA Rating1500 VA
  • Watts1350W
  • Output Voltage120VAC: 101 - 136VAC (208VAC: 186 - 236VAC)

被劃上刪除線的選項確實存在,但本站並無供貨。

  • 5 kVA / 1350 W line-interactive UPS protects critical loads
  • 2U rack/tower chassis fits standard cabinets and desktop setups
  • Eight NEMA 5-15R outlets power multiple devices from one unit
  • LCD panel plus DB-9, USB and RJ-45 ports enable local and remote monitoring
  • User-replaceable BM0087 battery module extends service life without downtime

1.5 kVA line-interactive UPS for rack or tower use

The MINUTEMAN EXR1500RT2UNC delivers 1500 VA and 1350 W of battery-backed power in a 2U form factor that fits a rack or stands as a tower. It accepts a wide input window of 80 to 164 VAC and auto-senses 50 or 60 Hz frequency. Eight NEMA 5-15R outlets supply connected equipment while a replaceable BM0087 battery module keeps service simple.

DB-9 USB RJ-45 ports plus Gigabit Ethernet surge

Management interfaces include DB-9, USB and an RJ-45 network port that hosts the supplied SNMP-NV6 card for remote monitoring. A 1 Gbit Ethernet in/out surge circuit protects data lines alongside the 1000 Joule AC surge rating. The unit operates from 0 to 40 °C in up to 95 % non-condensing humidity and carries cULus, FCC Class B, CE, NOM, EnergyStar 2.0 and RoHS2 approvals.

Replaces smaller desktop UPS units when runtime

At full load the battery runs for 2.5 minutes and at half load for 9 minutes, giving time for graceful shutdown or generator start. The 2U rack profile suits server rooms and network closets where floor space is limited. Buyers who need longer runtime at full load or higher power capacity should consider larger units.

商品特色

  • 5 kVA / 1350 W line-interactive UPS protects critical loads
  • 2U rack/tower chassis fits standard cabinets and desktop setups
  • Eight NEMA 5-15R outlets power multiple devices from one unit
  • LCD panel plus DB-9, USB and RJ-45 ports enable local and remote monitoring
  • User-replaceable BM0087 battery module extends service life without downtime

商品規格

BrandMINUTEMAN
SeriesEXR Series
ModelEXR1500RT2UNC
Input Voltage Range80 to 164VAC (150 - 271VAC)
Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
Input ConnectionNEMA 5-15P
VA Rating1500 VA
Watts1350W
Output Voltage120VAC: 101 - 136VAC (208VAC: 186 - 236VAC)
Outlets8
Outlet Type(8) NEMA 5-15R
Battery Run TimeFull/Half Load: 2.5 / 9 minutes
Battery ReplaceableBM0087
Interface PortDB-9, USB, RJ-45
ApprovalscULus (UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B, CE & NOM certified,EnergyStar 2.0, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU)
Rackmountable2U
Surge Energy Rating1000 Joules
Surge Protection1Gbit RJ45 Ethernet (in/out)
Temperature0 to 40°C (+32 to +104°F)
Humidity0 - 95% Non-Condensing
Dimensions3.48" x 18.96" x 17.32"
Weight43 lbs.
出貨重量19.96 kg
包裝尺寸483 × 439 × 89 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

What does the DB-9, USB and RJ-45 interface port combination actually let me monitor or control?

The DB-9 and USB ports provide local serial or USB management, while the RJ-45 port connects the included SNMP-NV6 network card for remote monitoring and alerts over Ethernet.

What physical space and mounting hardware are required for the 2U rack or tower installation?

The unit measures 3.48" high, 18.96" wide and 17.32" deep, weighs 43 lbs and fits a standard 2U rack opening; rack ears and tower feet are included for either orientation.

How do I install the SNMP-NV6 card and what step is commonly missed?

Power off the UPS, remove the interface slot cover, insert the SNMP-NV6 card firmly until seated, secure the retaining screws, then power on and configure the card's IP address — the step often missed is assigning a static IP before connecting to the network.