Line-interactive UPS delivers 3000 VA / 2700 W with 2.5 min runtime at full load and 10 min at half load in a 2U rack-mountable chassis

  • International Version120V
  • Input Voltage Range80 to 164VAC (150 - 271VAC)
  • Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
  • Input ConnectionNEMA L5-30P (10 ft.) (NEMA L6-30P)
  • VA Rating3000 VA
  • Watts2700 W

被劃上刪除線的選項確實存在,但本站並無供貨。

  • 3000 VA capacity backs critical equipment during outages
  • 5 minutes full-load runtime protects data before shutdown
  • 2U rackmount design fits standard server cabinets
  • Seven outlets including NEMA L5-30R serve diverse loads
  • 1000 joule surge rating plus gigabit Ethernet protection guards connected gear

Line-interactive 3000 VA UPS for rack

The Minuteman EXR3000RT2UNC is a 2U line-interactive uninterruptible power supply rated at 3000 VA and 2700 W. It accepts 120 V input through a NEMA L5-30P cord and delivers regulated output to seven outlets: six NEMA 5-20R and one NEMA L5-30R. The unit suits network closets, server racks or wall-mount installations where single-phase protection is required.

Thermal range 0 to 40 °C with 8-hour recharge

Operating temperature spans 0 to 40 °C in non-condensing humidity up to 95 %. Typical battery recharge takes eight hours after a discharge event. Surge energy rating is 1,000 joules and a 1 Gbit RJ-45 pass-through protects Ethernet links. Management interfaces include DB-9, USB and RJ-45 for monitoring software or network cards.

Replaces smaller VA units when runtime matters

At full load the battery provides 2.5 minutes of runtime; at half load it extends to 10 minutes. This steps up from lower-capacity UPS models that cannot sustain 2700 W. The jump is worthwhile when connected equipment needs enough reserve time for orderly shutdown or generator start-up. Buyers who need longer runtime at full load should consider external battery packs or higher-capacity units.

商品特色

  • 3000 VA capacity backs critical equipment during outages
  • 5 minutes full-load runtime protects data before shutdown
  • 2U rackmount design fits standard server cabinets
  • Seven outlets including NEMA L5-30R serve diverse loads
  • 1000 joule surge rating plus gigabit Ethernet protection guards connected gear

商品規格

BrandMINUTEMAN
SeriesEXR SERIES
ModelEXR3000RT2UNC
International Version120V
Input Voltage Range80 to 164VAC (150 - 271VAC)
Input Frequency50/60 Hz, +/- 6 Hz auto-sensing
Input ConnectionNEMA L5-30P (10 ft.) (NEMA L6-30P)
VA Rating3000 VA
Watts2700 W
Output Voltage120VAC: 101 - 136VAC (208VAC: 186 - 236VAC)
Outlets7
Outlet Type(6) NEMA 5-20R (1) NEMA L5-30R
Battery Run TimeFull Load: 2.5 min
Half Load: 10 min
Battery ReplaceableBM0089
Interface PortDB-9, USB, RJ-45
Rackmountable2U
Surge Energy Rating1,000 Joules (800 Joules)
Surge Protection1Gbit RJ45 Ethernet (in/out)
TemperatureOperating 0 to 40°C (+32 to +104°F)
Humidity0 - 95% Non-Condensing
Dimensions3.48" x 23.62" x 18.96"
Weight77.6 lbs.
出貨重量35.38 kg
包裝尺寸599 × 483 × 89 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How do I install the EXR3000RT2UNC in a rack, and what step do people miss?

Mount the 2U chassis using the included brackets, connect the 10 ft NEMA L5-30P plug to a 30 A branch circuit, then attach loads to the six NEMA 5-20R and one NEMA L5-30R outlets; the step often missed is configuring the USB, DB-9 or RJ-45 management interface so the UPS can signal shutdown before the 2.5 min full-load runtime expires.

Which battery module replaces the internal pack when it wears out?

The user-replaceable battery cartridge is MINUTEMAN part BM0089; swap it without tools after powering down and disconnecting the input cord.

What limits continuous operation when the UPS runs on battery at full 2700 W load?

The battery provides only 2.5 minutes at 2700 W, so runtime is the first constraint; after that the unit shuts down to protect the cells.