저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

DELL

DELL 3.84TB 24Gbps SAS RI TLC 2.5 SSD KPM7XRUG3T84 CPO

SKU CH-0END-BMN74

Provides 3.84 TB of read-intensive SAS storage in a 2.5-inch form factor for compatible Dell PowerEdge servers

  • InterfaceSAS
  • 84 TB capacity supports large read-intensive workloads
  • 24 Gbps SAS interface delivers high-throughput data transfer
  • Read-intensive TLC design optimised for endurance in server environments
  • 5-inch form factor fits standard enterprise drive bays
  • Validated across Dell PowerEdge servers and storage arrays

Capacity and interface

This Dell enterprise SSD provides 3.84TB of storage over a 24Gbps SAS interface. It uses TLC flash tuned for read-intensive workloads in 2.5-inch drive bays. The drive suits servers that need high-capacity, low-latency access to frequently read data.

Thermals and power

The SSD is designed for standard enterprise chassis airflow and typical SAS power envelopes. Normal operation stays within the thermal limits expected for 2.5-inch SAS drives in compatible PowerEdge servers. Firmware is updated to the latest vendor release before shipment.

Compatibility list

The drive is validated for a wide range of Dell PowerEdge rack, tower, modular and storage platforms including R640, R740, R750, R760, MX740c, MX750C, ME4024 and ME5024 models. Buyers whose servers are not on this qualification list should verify support with their hardware vendor before purchase.

주요 특징

  • 84 TB capacity supports large read-intensive workloads
  • 24 Gbps SAS interface delivers high-throughput data transfer
  • Read-intensive TLC design optimised for endurance in server environments
  • 5-inch form factor fits standard enterprise drive bays
  • Validated across Dell PowerEdge servers and storage arrays

사양

BrandDell
ModelKPM7XRUG3T84, MT0R5
InterfaceSAS

이 상품에 대한 질문

How is the 2.5-inch SAS SSD installed in a PowerEdge R750, and which step is often missed?

Slide the drive into the hot-plug bay until the carrier clicks, then press the release latch to lock it; the step often missed is fully engaging the latch so the SAS connector seats on the backplane.

What maintenance will the 3.84TB RI TLC drive need later?

No scheduled maintenance is required; the drive relies on internal wear-levelling and error correction, and replacement is only needed if SMART attributes report media exhaustion or a controller flags a predictive failure.

What limit appears first on the 24Gbps SAS link during sustained reads?

The 24Gbps SAS interface bandwidth ceiling is reached before the TLC NAND saturates, so sequential throughput tops out at the link rate rather than the flash speed.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.