我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

DELL

DELL 3.84TB 24Gbps SAS RI TLC 2.5 SSD KPM7XRUG3T84 CPO

SKU CH-0END-BMN74

Provides 3.84 TB of read-intensive SAS storage in a 2.5-inch form factor for compatible Dell PowerEdge servers

  • InterfaceSAS
  • 84 TB capacity supports large read-intensive workloads
  • 24 Gbps SAS interface delivers high-throughput data transfer
  • Read-intensive TLC design optimised for endurance in server environments
  • 5-inch form factor fits standard enterprise drive bays
  • Validated across Dell PowerEdge servers and storage arrays

Capacity and interface

This Dell enterprise SSD provides 3.84TB of storage over a 24Gbps SAS interface. It uses TLC flash tuned for read-intensive workloads in 2.5-inch drive bays. The drive suits servers that need high-capacity, low-latency access to frequently read data.

Thermals and power

The SSD is designed for standard enterprise chassis airflow and typical SAS power envelopes. Normal operation stays within the thermal limits expected for 2.5-inch SAS drives in compatible PowerEdge servers. Firmware is updated to the latest vendor release before shipment.

Compatibility list

The drive is validated for a wide range of Dell PowerEdge rack, tower, modular and storage platforms including R640, R740, R750, R760, MX740c, MX750C, ME4024 and ME5024 models. Buyers whose servers are not on this qualification list should verify support with their hardware vendor before purchase.

商品特色

  • 84 TB capacity supports large read-intensive workloads
  • 24 Gbps SAS interface delivers high-throughput data transfer
  • Read-intensive TLC design optimised for endurance in server environments
  • 5-inch form factor fits standard enterprise drive bays
  • Validated across Dell PowerEdge servers and storage arrays

商品規格

BrandDell
ModelKPM7XRUG3T84, MT0R5
InterfaceSAS

商品問答

How is the 2.5-inch SAS SSD installed in a PowerEdge R750, and which step is often missed?

Slide the drive into the hot-plug bay until the carrier clicks, then press the release latch to lock it; the step often missed is fully engaging the latch so the SAS connector seats on the backplane.

What maintenance will the 3.84TB RI TLC drive need later?

No scheduled maintenance is required; the drive relies on internal wear-levelling and error correction, and replacement is only needed if SMART attributes report media exhaustion or a controller flags a predictive failure.

What limit appears first on the 24Gbps SAS link during sustained reads?

The 24Gbps SAS interface bandwidth ceiling is reached before the TLC NAND saturates, so sequential throughput tops out at the link rate rather than the flash speed.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。